Specifications
Â
5 Year Warranty |
 |
Approvals: Â |
Â
Single Output |
||||
Model Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Maximum Output Power |
SMDA16A-S02Â |
5 ~ 5.99 VDC |
2.60 ~ 2.16 A |
±5% |
13W |
SMDA16A-S03Â |
6 ~ 8 VDC |
2.16 ~ 1.62 A |
±5% |
13W |
SMDA16A-S04Â |
8 ~ 11 VDC |
1.87 ~ 1.36 A |
±5% |
15W |
SMDA16A-S05Â |
11 ~ 13 VDC |
1.36 ~ 1.15 A |
±5% |
15W |
SMDA16A-S06Â |
13 ~ 16 VDC |
1.15 ~ 0.93 A |
±5% |
15W |
SMDA16A-S07Â |
16 ~ 21 VDC |
0.93 ~ 0.71 A |
±5% |
15W |
SMDA16A-S08Â |
21 ~ 27 VDC |
0.71 ~ 0.55 A |
±3% |
15W |
SMDA16A-S09 |
27 ~ 33 VDC |
0.55 ~ 0.45 A |
±5% |
15W |
SMDA16A-S10 |
33 ~ 36 VDC |
0.45 ~ 0.41 A |
±5% |
15W |
SMDA16A- S02, S03 are required to use AWG#16 / 4FT output cable.Â
SMDA16A- S05~S10 are required to use AWG#18 / 4FT output cable.Â
The regulation and efficiency are not guaranteed if changes the output cable
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
 |
240 |
VAC |
Operate Voltage Range |
Derate linearly from 100% load at 90VAC to 80% load at 80VAC |
80 |
 |
275 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Output Power Range |
See Rating Chart |
 |
 |
15 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
0.29 |
0.32 |
 |
A |
High Line Input Current |
Full load, Vin=240VAC |
0.17 |
0.19 |
 |
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
 |
 |
23 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
 |
 |
55 |
A |
Safety Ground Leakage Current |
Vin=264VAC, Fi=63Hz |
 |
 |
0.15 |
mA |
Efficiency |
Full Load, Vin=230VAC |
75 |
 |
85 |
% |
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
0.5 |
 |
1 |
% |
Over Voltage Protection |
 |
112 |
 |
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
 |
150 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
 |
 |
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
 |
 |
10 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
 |
 |
2 |
s |
Insulation Resistance |
 |
50 |
 |
 |
MΩ |
Ripple & Noise (Peak to Peak) |
 |
 |
 |
1 |
% |
Temperature Coefficient |
All output |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary, limit current<10mA |
 |
 |
4000 |
VAC |
Dielectric Withstanding Voltage(P-G) |
Primary to PE, limit current<10mA |
 |
 |
1500 |
VAC |
EMC Emission |
Compliance to EN55011(CISPR11), EN60601-1-2 |
B |
 |
 |
Class |
Â
Â
Â
Environmental |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 50â to 50% load at 70â |
-10 |
 |
70 |
°C |
Storage Temperature |
10~95% RH |
-40 |
 |
85 |
°C |
Operating Humidity |
non-condensing |
0 |
 |
95% |
RH |
Storage Humidity |
 |
0 |
 |
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
 |
 |
15 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
 |
 |
8 |
KV |
Mean Time Between Failure |
Operation Temperature at 25âJ, Calculated per MIL-HDBK-217F |
200K |
 |
 |
h |
Operating Altitude (Elevation) |
All Condition |
 |
 |
3000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
 |
 |
5 |
G |
Surge Voltage |
Line-Neutral |
 |
 |
1 |
KV |
Surge Voltage |
Line-PE & Neutral-PE |
 |
 |
2 |
KV |
Â
Mechanical Diagram |
Note:
|
Â
Derating Chart |
1. Operating Temperature: -10 to 70¢XC 2. Derate linearly from 100% load at 50¢XC to 50% load at 70¢XC  |