Specifications
3 Year Warranty |
|
Approvals: |
Single Output |
Model Number |
Output Voltage |
Output Current |
Total Regulation |
Ripple & Noise |
Maximum Output Power |
Typ. Efficiency |
Typ. No Load Consumption |
||||
Vo1 |
Vo2 |
Vo1 |
Vo2 |
Typ. |
Max* |
||||||
Typ. |
Max* |
||||||||||
SHFA200-S05(P) |
12.0 VDC |
12.0 VDC |
12.5A |
16.66A |
0.1A |
±3% |
120 |
150W |
200W |
90% |
0.21W |
SHFA200-S06(P) |
15.0 VDC |
12.0 VDC |
10.0 A |
13.33A |
0.1A |
±3% |
150 |
150W |
200W |
90% |
0.21W |
SHFA200-S07(P) |
19.0 VDC |
12.0 VDC |
7.89 A |
10.52A |
0.1A |
±3% |
190 |
150W |
200W |
90% |
0.21W |
SHFA200-S08(P) |
24.0 VDC |
12.0 VDC |
6.25 A |
8.33A |
0.1A |
±3% |
240 |
150W |
200W |
91% |
0.21W |
SHFA200-S09(P) |
30.0 VDC |
12.0 VDC |
5.35 A |
6.66A |
0.1A |
±3% |
240 |
150W |
200W |
91% |
0.21W |
SHFA200-S10(P) |
36.0 VDC |
12.0 VDC |
4.16 A |
5.55A |
0.1A |
±3% |
240 |
150W |
200W |
92% |
0.21W |
SHFA200-S11(P) |
48.0 VDC |
12.0 VDC |
3.12 A |
4.16A |
0.1A |
±3% |
240 |
150W |
200W |
92% |
0.21W |
*With 10 CFM Forced Air to max load / *Max1:Free Air Max2:Forced Air / *"P" means with optional Vo2 (This email address is being protected from spambots. You need JavaScript enabled to view it.)
Electrical Characteristics |
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Operate Voltage Range |
|
90 |
|
260 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Power Factor Correction |
|
0.90 |
|
1 |
 |
Output Power Range |
See Rating Chart |
|
|
200 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
|
3 |
|
A |
High Line Input Current |
Full load, Vin=240VAC |
|
1 |
|
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
|
|
50 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
|
|
100 |
A |
Safety Ground Leakage Current |
Vin=240VAC, F=60Hz |
|
|
0.25 |
mA |
Efficiency |
Full Load, Vin=230VAC |
(See rating chart.) |
|||
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
|
|
1 |
% |
Over Voltage Protection |
Latch off, recycle input to reset |
|
|
|
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
|
150 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
|
|
20 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
|
|
1 |
s |
Ripple & Noise (Peak to Peak) |
Full Load, Vin=90VAC |
(See rating chart.) |
|||
Insulation Resistance |
|
50 |
|
|
MΩ |
Temperature Coefficient |
All Condition |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary, limit current<10 mA |
4000 |
|
|
VAC |
Dielectric Withstanding Voltage(P-G) |
Primary to PE, limit current<10 mA |
2828 |
|
|
VAC |
EMC Emission |
Compliance to EN55022 (CISPR22) |
B |
|
|
Class |
Environmental |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.2 (Derate linearly from 100% load at 40°C to 50% load at 70°C) |
-10 |
|
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
4 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
200k |
|
|
h |
Operating Altitude (Elevation) |
All condition |
|
|
5000 |
m |
Vibration |
10 ~ 500Hz, 10min./1cycle, 60min. each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
kV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
kV |
Mechanical Diagram and Technical Charts |