Specifications
3 Year Warranty |
|
Approvals: |
Single Output |
PART NO. |
Setting Voltage Range (Factory setting, canât be adjusted) |
Output Current (Based on the output volt.) |
Max. Output Power |
Ripple & Noise |
Total Reg. |
Typ. Efficiency |
Typ. No Load Power |
Hold-up Time |
Protection Mode |
||
min |
max |
min |
max |
||||||||
(VDC) |
(VDC) |
(A) |
(A) |
(W) |
(mVp-p) |
(%) |
(%) |
(W) |
(ms) |
||
12.0 |
13.0 |
4.61 |
5.00 |
60 |
120 |
±5 |
84 |
0.5 |
12 |
Hiccup |
|
SHFA60-S06 |
13.0 |
16.0 |
3.75 |
4.67 |
60 |
130 |
±5 |
85 |
0.5 |
12 |
Hiccup |
SHFA60-S07 |
16.0 |
21.0 |
2.85 |
3.75 |
60 |
160 |
±5 |
85 |
0.5 |
12 |
Hiccup |
SHFA60-S08 |
21.0 |
27.0 |
2.22 |
2.85 |
60 |
200 |
±3 |
86 |
0.5 |
12 |
Hiccup |
SHFA60-S09 |
27.0 |
33.0 |
1.81 |
2.22 |
60 |
200 |
±3 |
86 |
0.5 |
12 |
Hiccup |
SHFA60-S10 |
33.0 |
40.0 |
1.50 |
1.81 |
60 |
200 |
±3 |
86 |
0.5 |
12 |
Hiccup |
Electrical Characteristics & General Specifications |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Input Operate Voltage Range |
Detail to see Fig.1 (Derate linearly from 100% load at 90VAC to 80% load at 80VAC) |
80 |
|
275 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Output Power Range |
See Rating Chart |
|
|
60 |
W |
Low Line Input Current |
Full Load, Vin=100VAC |
|
0.8 |
|
A |
High Line Input Current |
Full Load, Vin=240VAC |
|
0.4 |
|
A |
Low Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=100VAC |
|
|
31 |
A |
High Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=240VAC |
|
|
62 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
|
|
0.25 |
mA |
Efficiency |
Full Load, Vin=230VAC, Detail to see Rating Chart |
See Rating Chart |
|||
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
|
|
1 |
% |
Over Voltage Protection |
|
112 |
|
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
|
150 |
% |
Time of Transient Response |
Full Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
See Rating Chart |
|||
Start-up time |
Full Load, Vin=100~240VAC |
|
|
2 |
s |
Insulation Resistance |
|
50 |
|
|
MΩ |
Temperature Coefficient |
All Condition |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage (P-S) |
Primary to Secondary, limit current <10mA |
|
|
4000 |
VAC |
Dielectric Withstanding Voltage (P-G) |
Primary to PE, limit current <10mA |
|
|
1500 |
VAC |
EMC Emission |
Compliance to EN55011 (CISPR11), EN60601-1-2 |
B |
|
|
Class |
Short Circuit Protection |
Auto Recovery |
Cooling |
Free Air Convection |
Flammability Rating |
UL94V-1 |
Protection Classes |
Class I |
Safety |
IEC60601-1 Edition3.1, ES60601-1:2005(R2012), CSAC22.2 NO.60601-1:14, EN60601-1:2006/A1:2013 |
Environmental |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.2 (Derate linearly from 100% load at 50°C to 50% load at 70°C) |
-10 |
|
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
15 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
8 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
200k |
|
|
h |
Operating Altitude (Elevation) |
All condition |
|
|
3000 |
m |
Vibration |
10 ~ 500Hz, 10min./1cycle, 60min. each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
kV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
kV |
Mechanical Diagram and Technical Charts |