Specifications
5 Year Warranty |
|
Approvals: |
ELECTRICAL SPECIFICATIONS |
PART NUMBER |
JLPA120JU -S0700S-E |
JLPA120JU-S1050S-E |
JLPA120JU -S1250S-E |
JLPA120JU -S1400S-E |
JLPA120JU -S2100S-E |
JLPA120JU- S2400S-E |
JLPA120JU -S02800S-E |
|
OUTPUT |
DC VOLTAGE |
103-171V |
69-114V |
58-96V |
52-86V |
34-57V |
30-50V |
26-43V |
CONSTANT CURRENT REGION Note.4 |
700mA |
1050mA |
1250mA |
1400mA |
2100mA |
2400mA |
2800mA |
|
RATED POWER |
120W |
|||||||
RIPPLE & NOISE(max.) Note.2 |
1.31V |
0.92V |
0.7V |
0.61V |
0.45V |
0.42V |
0.3V |
|
CURRENT TOLERANCE Note.3 |
±5.0% |
|||||||
LINE REGULATION |
±2.0% |
|||||||
LOAD REGULATION |
±3.0% |
|||||||
SETUP, RISE TIME(Typ.) Note.7 |
1000ms/50ms 115VAC at full load 400ms/50ms 230VAC |
|||||||
INPUT |
VOLTAGE RANGE Note.5 |
100 ~265VAC |
||||||
FREQUENCY RANGE |
47 ~ 63Hz |
|||||||
POWER FACTOR(Typ.) |
0.99@115VAC 60HZ 0.95@230VAC 50HZ |
|||||||
EFFICIENCY(Typ.) |
93%@220V 100%Load |
93%@220V 100%Load |
92%@220V 100%Load |
91%@220V 100%Load |
91%@220V 100%Load |
90%@220V 100%Load |
90%@220V 100%Load |
|
AC CURRENT(Typ.) |
1.16A/115VAC 0.6A/230VAC |
|||||||
INRUSH CURRENT(Typ.) |
COLD START 21A ( Twidth=270us measured at 50% Ipeak ) at 230VAC |
|||||||
LEAKAGE CURRENT |
<0.75mA/265VAC |
PROTECTIONS & CONDITIONS |
PROTECTION |
OVER CURRENT Note.4 |
95 ~ 108% |
||||||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
||||||||
SHORT CURRENT |
Hiccup mode, recovers automatically after fault condition is removed |
|||||||
OVER VOLTAGE |
185V |
123V |
104V |
100V |
62V |
54V |
47V |
|
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
||||||||
OVER TEMP. |
Hiccup mode, recovers automatically after fault condition is removed |
|||||||
ENVIRONMENT |
WORKING TEMP. |
-35 ~ +70℃ (Refer to “Derating Curve”) |
||||||
WORKING HUMIDITY |
10 ~ 100% RH non-condensing |
|||||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 5 ~ 100% RH |
|||||||
TEMP. COEFFICIENT |
±0.03%℃ (0~50℃) |
|||||||
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY & EMC & GENERAL INFORMATION |
SAFETY & EMC |
SATETY STANDARDS Note.6 |
Meet UL8750, UL935, UL1012, CSA-C22.2 No.107.1, EN61347-1, EN61347-2-13 |
WITHSTAND VOLTAGE |
I/P – O/P: 3.75kVAC,I/P-FG:2KVAC |
|
ISOLTATION RESISTANCE |
I/P – O/P: 100M Ohms / 500VDC /25℃ / 70% RH |
|
EMC EMISSION |
Compliance to EN55015, EN61000-3-2 Class C (≥60% load); EN61000-3-3 |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge 2kV), criteria A |
|
OTHERS |
MTBF |
314khrs min. MIL-HDBK-217F (25℃) |
DIMENSIION |
124(150)*68*42MM(L*W*H) |
|
PACKING |
715±10g |
|
NOTE |
|
MECHANICAL SPECIFICATION |
DERATING CURVE |
DIMMING FUNCTION |
0-10V Analog Dimming |
||||||||||
1:Positive logic |
2:Negative logic |
|||||||||
|
||||||||||
NOTE: 1. If the dimming function is not used, all wire NC. 2. Io is actual output current and Ir is rated current without dimming control. 3. The dimmer can also be replaced by an active 0-10V voltage source signal or passive components like resistors and Zener. 4. The dimming signal is allowed to be less than 1V, when it for 0-1V, the connected LEDs may flicker. Keeping dimming voltage greater than 1V in application is strongly recommended. 5. Do not connect the GND of DIM-(gray) to the output. Otherwise, the LED driver can not work normally. |
0-5V Analog Dimming |
||||||||||
1:Positive logic |
2:Negative logic |
|||||||||
|
||||||||||
NOTE: 1.If the dimming function is not used, all wire NC. 2. Io is actual output current and Ir is rated current without dimming control. 3. The dimmer can also be replaced by an active 0-5V voltage source signal or passive resistors and Zener. 4. Do not connect the GND of DIM-(gray) to the output. Otherwise, the LED driver can not work normally. |