Specifications
3 Year Warranty |
|
Approvals: |
SPECIFICATION |
PART NUMBER |
KLDC60JU-S0640M |
KLDC60JU-S0700M |
KLDC60JU-S0900M |
KLDC60JU-S1050M |
OUTPUT |
DC VOLTAGE |
33-94V |
33-87V |
40-67V |
33-57V |
CONSTANT CURRENT REGION Note.4 |
640mA |
700mA |
900mA |
1050mA |
|
RATED POWER |
60W |
||||
RIPPLE & NOISE(max.) Note.2 |
0.42V |
0.36V |
0.31V |
0.25V |
|
CURRENT TOLERANCE Note.3 |
±5.0% |
||||
LINE REGULATION |
±1.0% |
||||
LOAD REGULATION |
±1.0% |
±1.0% |
±1.0% |
±1.0% |
|
SETUP, RISE TIME(Typ.) Note.7 |
240ms/40ms 12VDC at full load 250ms/98ms 24VDC at full load |
||||
INPUT |
VOLTAGE RANGE Note.5 |
10 ~ 30VDC |
|||
EFFICIENCY(Typ.) |
94% |
94% |
94% |
93.5% |
|
DC CURRENT(Typ.) |
5.4A/12VDC 2.6A/24VDC |
||||
INRUSH CURRENT(Typ.) |
COLD START 68A at 12VDC |
||||
LEAKAGE CURRENT |
<0.6mA/12VDC |
||||
PROTECTION |
OVER CURRENT Note.4 |
95 ~ 108% |
|||
Protection type: Constant current limiting, recovers automatically after fault condition is removed |
|||||
SHORT CURRENT |
Hiccup mode, recovers automatically after fault condition is removed |
||||
OVER VOLTAGE |
99V |
99V |
91 |
67V |
|
Protection type: Hiccup mode, recovers automatically after fault condition is removed |
|||||
OVER TEMP. |
Hiccup mode, recovers automatically after fault condition is removed |
||||
ENVIRONMENT |
WORKING TEMP. |
-35 ~ +70℃ (Refer to “Derating Curve”) |
|||
WORKING HUMIDITY |
10 ~ 100% RH non-condensing |
||||
STORAGE TEMP., HUMIDITY |
-40 ~ +85℃, 5 ~ 100% RH |
||||
TEMP. COEFFICIENT |
±0.3%℃ (0~50℃) |
||||
VIBRATION |
10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes |
SAFETY & EMC |
SATETY STANDARDS Note.6 |
Meet UL8750, UL935, UL1012, CSA-C22.2 No.107.1, EN61347-1, EN61347-2-13 |
ISOLTATION RESISTANCE |
I/P – FG: 100M Ohms / 500VDC /25℃ / 70% RH |
|
EMC EMISSION |
Compliance to EN55015, EN61000-3-2 Class C (≥60% load); EN61000-3-3 |
|
EMC IMMUNITY |
Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024 |
|
OTHERS |
MTBF |
390khrs min. MIL-HDBK-217F (25℃) |
DIMENSIION |
104(124)*49*33MM (L*W*H) |
|
PACKING |
310g±10g |
|
NOTE |
|
MECHANICAL DIAGRAMS |
KLDC60JU SERIES Non-Dimming Function
KLDC60JUD SERIES Dimming Function
Dimming Function |
0-10V Analog Dimming |
|
NOTE:
1. If the dimming function is not used, all wire NC.
2. Io is actual output current and Ir is rated current without dimming control.
3. The dimmer can also be replaced by an active 0-10V voltage source signal or passive components like resistors and zener
4. Do not connect the GND of DIM-(gray) to the output. Otherwise, the LED driver can not work normally.
Datasheet PDF