Print this page

KLDC40JU(D) SERIES


40W DC Input Constant Current LED Driver


  • Wide Input Voltage 10 to 30VDC
  • Over Voltage / Short Circuit / Over Temperature Protection
  • High Efficiency (up to 94%)
  • Dimming function Optional ( 0~10V /PWM/ Timer )
  • IP67 Waterproof Rating, Fully isolated 
  • Comply to worldwide safety regulations for lighting
  • Cooling by free air convection
  • Suitable for LED lighting & moving sign applications, for dry / damp / wet locations

Specifications

 

 

3 Year Warranty

 

Approvals:  

 

SPECIFICATION

PART NUMBER

KLDC40JU(D)-

S0450M

KLDC40JU(D)-

S0700M

KLDC40JU(D)-S1050M

KLDC40JU(D)-

S1200M

OUTPUT

DC VOLTAGE

33-88V

33-58V

33-39V

33-36V

CONSTANT CURRENT REGION Note.4

450mA

700mA

1050mA

1200mA

RATED POWER

40W

RIPPLE & NOISE(max.) Note.2

0.35V

0.25V

0.25V

0.25V

VOLTAGE TOLERANCE Note.3

±5.0%

LINE REGULATION

±1.0%

LOAD REGULATION

±1.0%

±1.0%

±1.0%

±1.0%

SETUP, RISE TIME(Typ.) Note.7

 250ms/50ms 12VDC at full load       250ms/100ms 24VDC at full load

INPUT

VOLTAGE RANGE Note.5

10 ~ 30VDC

EFFICIENCY(Typ.)

94%

94%

94%

94%

DC CURRENT(Typ.)

3.7A/12VDC     1.8A/24VDC

INRUSH CURRENT(Typ.)

COLD START 68A at 12VDC

LEAKAGE CURRENT

<0.6mA/12VDC

PROTECTION

OVER CURRENT Note.4

95 ~ 108%

Protection type: Constant current limiting, recovers automatically after fault condition is removed

SHORT CURRENT

Hiccup mode, recovers automatically after fault condition is removed

OVER VOLTAGE

99V

66V

44V

44V

Protection type: Hiccup mode, recovers automatically after fault condition is removed

OVER TEMP.

Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.

-35 ~ +70 (Refer to “Derating Curve”)

WORKING HUMIDITY

10 ~ 100% RH non-condensing

STORAGE TEMP., HUMIDITY

-40 ~ +85, 5 ~ 100% RH

TEMP. COEFFICIENT

±0.3% (0~50)

VIBRATION

10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes

 

SAFETY & EMC

SATETY STANDARDS Note.6

EN61347-1, EN61347-2-13

ISOLTATION RESISTANCE

I/P – FG: 100M Ohms / 500VDC /25 / 70% RH

EMC EMISSION

Compliance to EN55015, EN61000-3-2 Class C (60% load); EN61000-3-3

EMC IMMUNITY

Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024

OTHERS

MTBF

430khrs min.      MIL-HDBK-217F (25)

DIMENSIION

104(124)*49*33MM (L*W*H)

PACKING

310g

NOTE

  1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25¢J of ambient temperature.
  2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. Tolerance: includes set up tolerance, line regulation & load regulation.
  4. Derating may be needed under low input voltages. Please check the static characteristics for details.
  5. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minutes.
  6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC DIRECTIVE on the complete installation again.
  8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
  9. To fulfill requirements of the latest ERP regulation for lighting fixtures, this LED power supply can only be used behind switch without permanently connected to the mains.

 

CHARACTERISTIC CHARTS

 

MECHANICAL DIAGRAMS

KLDC40JU SERIES  Non-Dimming Function 

 

KLDC40JUD SERIES  Dimming Function

 

 

Dimming Function

 

TIMER Dimming

n  NOTE:

   1. The dimming time can be customized according to different order.

 

 

0-10V Analog Dimming

 

Input Dimming Voltage

0-12V

Normal 10-11V

Input Source Current

0-10mA

47 ~ 63Hz

 

 

NOTE:

1.If the dimming function is not used, all wire NC.

2. Io is actual output current and Ir is rated current without dimming control.

3. For the driver to operate properly, the load voltage must be maintained above the input voltage t, proximally 50% of the

  max. output voltage for any given model.

4. The dimming signal is allowed to be less than 1V, when it for 0-1V, the connected LEDs may flicker. Keeping dimming

  voltage greater than 1V in application is strongly recommended.

5. Do not connect the GND of dimming (gray) to the output. Otherwise, the LED driver can not work normally.

 

PWM Dimming

 