STUA180 SERIES


180W U-Bracket Power Supply for I.T. Equipment


  • Wide Operating Voltage 90 to 260 VAC, 47 to 63Hz 
  • Internal EMI Filter
  • Active Power Factor Correction
  • Crowbar Mode Over Voltage Protection
  • Input Surge Current and Over Load Protection
  • Single Output 

Specifications

 

 

3 Year Warranty

 

Approvals: 

 

Single Output

Model Number

Output Voltage

Max. Output Current

Total Regulation

Maximum Output Power

STUA180-S05

12 VDC

14.58 A

±5%

175W

STUA180-S08

24 VDC

7.50  A

±3%

180W

STUA180-S10

36 VDC

5.00 A

±2%

180W

STUA180-S11

48 VDC

3.75  A

±2%

180W

 *STUA180-S05 is required to use DINKLE#DT-2N-B01W-04.

 

Electrical Characteristics

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Safety Approvals Input Voltage Range

Safety Approval & Specification in Label

100

 

240

VAC

Operate Voltage Range

 

90

 

260

VAC

Input Frequency

Sine wave

47

 

63

Hz

Power Factor Correction

lo=Full load, Vin=240AC

0.95

 

1

 

Output Power Range

See Rating Chart

 

 

180

W

Low Line Input Current

Full load, Vin=100VAC

 

2.3

 

A

High Line Input Current

Full load, Vin=240VAC

 

0.95

 

A

Low Line Input Inrush Current

Full load, 25°C, Cool start, Vin=100VAC

 

 

60

A

High Line Input Inrush Current

Full load, 25°C, Cool start, Vin=240VAC

 

 

144

A

Safety Ground Leakage Current

Vin=240VAC, Fi=60Hz

 

 

0.75

mA

Efficiency

Full Load, Vin=230VAC

 

 

87

%

Line Regulation

Full Load, Vin=100~120VAC

0.5

 

1

%

Load Regulation

Vin=230VAC, 10~90% Load Change at Condition

2

 

5

%

Over Voltage Protection

Over Voltage Protection

112

 

132

%

Over Load Protection

Recovers automatically after fault condition is removed

110

 

150

%

Time of Transient Response

Io=Full Load to Half Load, Vin=110VAC

 

 

4

ms

Hold-Up Time

Full Load, Vin=100VAC

 

 

20

ms

Start Up Time

Full Load, Vin=100~240VAC

 

 

2

s

Ripple & Noise (Peak to Peak)

 

 

 

1

%

Temperature Coefficient

Full Load, Vin=100~240VAC

 

 

±0.04

%/°C

Dielectric Withstanding Voltage (P-S)

Primary to Secondary

 

 

4242

VDC

Dielectric Withstanding Voltage (P-G)

Primary to PE

 

 

2121

VDC

EMC Emission

Compliance to EN55022 (CISPR22)

 

 

B

Class

 

 

Environmental

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Operating Temperature

Derate linearly from 100% load at 50°C to 50% load at 70°C

0

 

70

°C

Storage Temperature

 10~95% RH

-40

 

85

°C

Operating Humidity

 non-condensing

0

 

95%

RH

Storage Humidity

 

0

 

95%

RH

Electro Static Discharge

Air Discharge, IEC61000-4-2

 

 

8

KV

Electro Static Discharge

Contact Discharge, IEC61000-4-2

 

 

4

KV

Mean Time Between Failure

Operation Temperature at 25℃, Calculated per MIL-HDBK-217F

100K

 

 

h

Operating Altitude (Elevation)

All Condition

 

 

2000

m

Vibration

10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes

 

 

5

G

Surge Voltage

  Line-Neutral

 

 

1

KV

Surge Voltage

  Line-PE & Neutral-PE

 

 

2

KV

 

 

Mechanical Diagram

PIN CHART

PIN

MODEL

1

2

3

4

5

6

7

8

STUA180-SXX

RTN

RTN

RTN

RTN

OUT

OUT

OUT

OUT

Note:

  1. Dimensions are shown in mm.
  2. Weight: 521gs approx.
  3. Input connector mates with Molex housing  
         09-52-4034 and Molex 2478 series crimp terminal.
  4. Output connector mates with Molex housing  
         09-52-4084 and Molex 2478 series crimp 

Derating Chart

 

1. Operating Temperature: 0 to 70°C

2. Derate linearly from 100% load at 50°C to 50% load at 70°C

 

STUA180 - MEPOS ELECTRONICS