Specifications
3 Year Warranty |
|
Approvals: |
Single Output |
||||
Model Number |
Output Voltage |
Output Current |
Total Regulation |
Max. Output Power |
* STDA65-S01 |
3 ~ 5 VDC |
16.6 ~ 10.0 A |
±7% |
50W |
STDA65-S02 |
5 ~ 5.99 VDC |
13.0 ~ 10.8 A |
±7% |
65W |
STDA65-S03 |
6 ~ 8 VDC |
11.6 ~ 8.70 A |
±5% |
69.6W |
STDA65-S04 |
8 ~ 11 VDC |
9.37 ~ 6.81 A |
±5% |
75W |
STDA65-S05 |
11 ~ 13 VDC |
6.66 ~ 6.15 A |
±5% |
80W |
STDA65-S06 |
13 ~ 16 VDC |
6.15 ~ 5.00 A |
±5% |
80W |
STDA65-S07 |
16 ~ 21 VDC |
5.00 ~ 3.80 A |
±5% |
80W |
STDA65-S08 |
21 ~ 27 VDC |
3.80 ~ 2.96 A |
±5% |
80W |
STDA65-S09 |
27 ~ 33 VDC |
2.96 ~ 2.42 A |
±3% |
80W |
STDA65-S10 |
33 ~ 40 VDC |
2.42 ~ 2.00 A |
±3% |
80W |
STDA65-S11 |
40 ~ 48 VDC |
2.00 ~ 1.66 A |
±3% |
80W |
* STDA65-S01 is not in compliance with DoE VI.
Multi Output |
|||||||||||||||||
Model Number |
Output 1 |
Output 2 |
Output 3 |
Output 4 |
Max. Output Power |
||||||||||||
Vonom |
Iomin |
Iomax |
Regmax |
Vonom |
Iomin |
Iomax |
Regmax |
Vonom |
Iomin |
Iomax |
Regmax |
Vonom |
Iomin |
Iomax |
Regmax |
||
STDA65-D00 |
+3.3V |
1.4A |
7A |
±7% |
+12V |
0.55A |
2.75A |
±5% |
|
|
|
|
|
|
|
|
56.1W |
STDA65-D01 |
+5V |
0.7A |
7A |
±5% |
+12V |
0.7A |
3A |
±5% |
|
|
|
|
|
|
|
|
65W |
STDA65-D02 |
+5V |
1.4A |
7A |
±5% |
+15V |
0.6A |
3A |
±6% |
|
|
|
|
|
|
|
|
65W |
STDA65-D03 |
+5V |
1.4A |
7A |
±5% |
+24V |
0.4A |
2A |
±5% |
|
|
|
|
|
|
|
|
65W |
STDA65-D04 |
+3.3V |
1.4A |
7A |
±7% |
+5V |
0.6A |
3A |
±5% |
|
|
|
|
|
|
|
|
38.1W |
STDA65-D15 |
+5V |
1.4A |
7A |
±5% |
|
|
|
|
-24V |
0.4A |
1A |
±10% |
|
|
|
|
59W |
STDA65-T00 |
+3.3V |
1.4A |
7A |
±7% |
+12V |
0.6A |
3A |
±5% |
-12V |
0.16A |
0.8A |
±5% |
|
|
|
|
65W |
STDA65-T01 |
+5V |
0.6A |
6A |
±5% |
+12V |
0.3A |
3A |
±5% |
-5V |
0A |
0.8A |
±5% |
|
|
|
|
65W |
STDA65-T02 |
+5V |
0.6A |
6A |
±5% |
+12V |
0.6A |
3A |
±5% |
-12V |
0A |
0.8A |
±5% |
|
|
|
|
65W |
STDA65-T03 |
+5V |
0.6A |
6A |
±5% |
+15V |
0.6A |
3A |
±6% |
-15V |
0A |
0.8A |
±5% |
|
|
|
|
65W |
STDA65-T04 |
+5V |
0.7A |
7A |
±5% |
+24V |
0.2A |
2A |
±5% |
-24V |
0A |
0.8A |
±5% |
|
|
|
|
65W |
STDA65-T05 |
+5V |
0.6A |
6A |
±5% |
+24V |
0.2A |
2A |
±5% |
-12V |
0A |
0.8A |
±5% |
|
|
|
|
65W |
STDA65-T06 |
+3.3V |
0.7A |
7A |
±7% |
+12V |
0.6A |
3A |
±5% |
-5V |
0A |
0.8A |
±5% |
|
|
|
|
63.1W |
* STDA65-403 |
+5V |
0.6A |
3.5A |
±5% |
+24V |
0.1A |
1.5A |
±5% |
+12V |
0A |
0.25A |
±5% |
-12V |
0A |
0.15A |
5% |
65W |
*STDA65-403 is not in compliance with DoE VI. STDA65-S01-S06 are required to use AWG#16X5C/4FT output cable. STDA65-S07 are required to use AWG#16X2C/4FT output cable. STDA65-S08~S09 are required to use AWG#18X2C/6FT output cable. STDA65-S10~S11 are required to use AWG#20X2C/6FT output cable. STDA65-DXX,TXX are required to use AWG#16X5C/4FT+core output cable. STDA65-D00,D04,T00,T06 are required to use AWG#16X5C/2FT+core output cable. The regulation and efficiency will be changed by modified output cable. |
Electrical Characteristics(Single Output) |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Operate Voltage Range |
|
90 |
|
264 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Output Power Range |
See Rating Chart |
|
|
80 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
|
1.9 |
|
A |
High Line Input Current |
Full load, Vin=240VAC |
|
0.79 |
|
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
|
|
30 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
|
|
72 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
|
|
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC |
65 |
|
88 |
% |
Line Regulation |
Full Load, Vin=100~120VAC |
0.5 |
|
1 |
% |
Load Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
3 |
|
7 |
% |
Over Voltage Protection |
Over Voltage Protection |
112 |
|
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
|
150 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
|
|
12 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
|
|
2 |
S |
Ripple & Noise (Peak to Peak) |
|
|
|
1 |
% |
Temperature Coefficient |
Full Load, Vin=100~240VAC |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary |
|
|
4242 |
VDC |
Dielectric Withstanding Voltage(P-G) |
Primary to PE |
|
|
2121 |
VDC |
EMC Emission |
Compliance to EN55022(CISPR22) |
|
|
B |
Class |
Environmental(Single Output) |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 40℃ to 50% load at 70℃ |
-20 |
|
70 |
°C |
Storage Temperature |
10~95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
4 |
KV |
Mean Time Between Failure |
Operation Temperature at 25℃, Calculated per MIL-HDBK-217F |
100K |
|
|
h |
Operating Altitude (Elevation) |
All Condition |
|
|
5000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
KV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
KV |
Environmental(Multi Output) |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 40℃ to 50% load at 70℃ |
0 |
|
70 |
°C |
Storage Temperature |
10~95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
4 |
KV |
Mean Time Between Failure |
Operation Temperature at 25℃, Calculated per MIL-HDBK-217F |
100K |
|
|
h |
Operating Altitude (Elevation) |
All Condition |
|
|
5000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
KV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
KV |
Mechanical Diagram |
Note:
|
Derating Chart |
STDA65-S01 1. Operating Temperature: 0 to 70°C 2. Derate linearly from 100% load at 25°C to 50% load at 70°C
STDA 65-S02~S11, STDA65-DXX, STDA65-TXX, STDA65-4XX 1. Operating Temperature: 0 to 70°C 2. Derate linearly from 100% load at 40°C to 50% load at 70°C |
Datasheet PDF