Specifications
Â
3 Year Warranty |
 |
Approvals:Â Â |
Â
Single Output |
PART NO. |
Setting Voltage Range (Factory setting, canât be adjusted) |
Output Current (Based on the output volt.) |
Max. Output Power |
Ripple & Noise |
Total Reg. |
Typ. Efficiency |
Typ. No-Load Power |
Hold-up Time |
Protect Mode |
(VDC) |
(A) |
(W) |
(mVp-p) |
(%) |
(%) |
(W) |
(ms) |
||
STFA151-S04 |
9.0 |
16.0 |
144 |
90 |
±5 |
83 |
3.5 |
16 |
Hiccup |
STFA151-S05 |
12.0 |
12.5 |
150 |
120 |
±5 |
85 |
3.5 |
16 |
Hiccup |
STFA151-S06 |
15.0 |
10.0 |
150 |
150 |
±5 |
85 |
3.5 |
16 |
Hiccup |
STFA151-S07 |
18.0 |
8.33 |
150 |
180 |
±4 |
85 |
3.5 |
16 |
Hiccup |
STFA151-S08 |
24.0 |
6 25. |
150 |
200 |
±3 |
86 |
3.5 |
16 |
Hiccup |
STFA151-S09 |
30.0 |
5.00 |
150 |
300 |
±2 |
86 |
3.5 |
16 |
Hiccup |
STFA151-S10 |
36.0 |
4.17 |
150 |
300 |
±2 |
86 |
3.5 |
16 |
Hiccup |
STFA151-S11 |
48.0 |
3.13 |
150 |
300 |
±2 |
86 |
3.5 |
16 |
Hiccup |
Â
Electrical Characteristics |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
100 |
 |
240 |
VAC |
Input Operate Voltage Range |
Detail to see Fig.1 |
90 |
 |
260 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Power Factor Correction |
Io=Full load, Vin=240VAC |
0.95 |
 |
1 |
 |
Output Power Range |
See Rating Chart |
 |
 |
150 |
W |
Low Line Input Current |
Full Load, Vin=100VAC |
 |
2.0 |
 |
A |
High Line Input Current |
Full Load, Vin=240VAC |
 |
0.8 |
 |
A |
Low Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=100VAC |
 |
 |
40 |
A |
High Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=240VAC |
 |
 |
100 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
 |
 |
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC, Detail  to see Rating Chart |
See Rating Chart |
|||
Line Regulation |
Full Load, Vin=100~120VAC |
0.5 |
 |
1 |
% |
Load  Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
2 |
 |
5 |
% |
Over Voltage Protection |
Over Voltage Protection |
112 |
 |
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
 |
150 |
% |
Time of Transient Response |
Full Load, Vin=110VAC |
 |
 |
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
See Rating Chart |
|||
Start-up time |
Full Load, Vin=100~240VAC |
 |
 |
3 |
s |
Temperature Coefficient |
Full load, Vin=100~240VAC |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage (P-S) |
Primary to Secondary |
 |
 |
4242 |
VDC |
Dielectric Withstanding Voltage (P-G) |
Primary to PE |
 |
 |
2121 |
VDC |
EMC Emission |
Compliance to EN55022 (CISPR22) |
 |
 |
B |
Class |
Short Circuit Protection |
 Auto Recovery |
Cooling |
 Free Air Convection |
Flammability Rating |
 UL94V-1 |
Protection Classes |
 Class I |
Safety |
 IEC 62368-1 Edition 2.0, UL 62368-1, CAN/CSA-C22.2 NO.62368-1-14, EN 62368-1:2014 |
Â
Environmental |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.2 (Derate linearly from 100% load at 50°C to 50% load at 70°C) |
0 |
 |
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-40 |
 |
85 |
°C |
Operating Humidity |
non-condensing |
0 |
 |
95% |
RH |
Storage Humidity |
 |
0 |
 |
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
 |
 |
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
 |
 |
4 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
100k |
 |
 |
h |
Operating Altitude (Elevation) |
All condition |
 |
 |
2000 |
m |
Vibration |
10 ~ 500Hz, 10min./1cycle, 60min. each along X, Y, Z axes |
 |
 |
5 |
G |
Surge Voltage |
Line-Neutral |
 |
 |
1 |
kV |
Surge Voltage |
Line-PE & Neutral-PE |
 |
 |
2 |
kV |