Specifications
Â
3 Year Warranty |
 |
Approvals:Â |
Â
Single Output |
Model Number |
Output Voltage (Factory setting, canât be adjusted) |
Output Current (Based on the output volt.) |
Total Regulation |
Maximum Output Power |
Typ. Efficiency |
Typ. No Load Consumption |
STDA151B-S05 |
12.0 VDC |
12.5 A |
±5% |
150W |
88% |
0.21W |
STDA151B-S06 |
15.0 VDC |
10.0 A |
±5% |
150W |
88% |
0.21W |
STDA151B-S07 |
19.0 VDC |
7.89 A |
±5% |
150W |
89% |
0.21W |
STDA151B-S08 |
24.0 VDC |
6.25 A |
±4% |
150W |
89% |
0.21W |
STDA151B-S09 |
30.0 VDC |
5.00 A |
±3% |
150W |
90% |
0.21W |
STDA151B-S10 |
36.0 VDC |
4.16 A |
±3% |
150W |
90% |
0.21W |
STDA151B-S11 |
48.0 VDC |
3.12 A |
±3% |
150W |
91% |
0.21W |
.
Â
Electrical Characteristics |
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
100 |
 |
240 |
VAC |
Operate Voltage Range |
 |
90 |
 |
260 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Power Factor Correction |
 |
0.95 |
 |
1 |
 |
Output Power Range |
See Rating Chart |
 |
 |
150 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
 |
2 |
 |
A |
High Line Input Current |
Full load, Vin=240VAC |
 |
0.8 |
 |
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
 |
 |
60 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
 |
 |
120 |
A |
Efficiency |
Full Load, Vin=230VAC, Detail to see Rating Chart |
88 |
 |
91 |
% |
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
 |
 |
1 |
% |
Over Voltage Protection |
Latch off, recycle input to reset |
112 |
 |
132 |
% |
Over Load Protection |
Nil.But, Output protected to short circuit conditions |
 |
 |
 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
 |
 |
4 |
ms |
Hold-Up Time |
Full Load, Vin=110VAC |
 |
 |
16 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
 |
 |
2 |
s |
Insulation Resistance |
Primary to Secondary, 500VDC,25°XC/ 70% RH |
50 |
 |
 |
MΩ |
Temperature Coefficient |
All Condition |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary, limit current<10 mA |
 |
 |
4242 |
VDC |
EMC Emission |
Compliance to EN55032 (CISPR32), EN55024 |
B |
 |
 |
Class |
Â
Â
Environmental |
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.2 (Derate linearly from 100% load at 40°C to 50% load at 70°C) |
-20 |
 |
70 |
°C |
Storage Temperature |
 10~95% RH |
-40 |
 |
85 |
°C |
Operating Humidity |
 non-condensing |
0 |
 |
95% |
RH |
Storage Humidity |
 |
0 |
 |
95% |
RH |
Electro Static Discharge |
 Air Discharge, IEC61000-4-2 |
 |
 |
8 |
kV |
Electro Static Discharge |
 Contact Discharge, IEC61000-4-2 |
 |
 |
4 |
kV |
Mean Time Between Failure |
 Operation Temperature at 25°C, Calculated per MIL-HDBK-217F |
100k |
 |
 |
h |
Operating Altitude (Elevation) |
 All Condition |
 |
 |
5000 |
m |
Vibration |
 10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
 |
 |
5 |
G |
Surge Voltage |
 Line-Neutral |
 |
 |
1 |
kV |
Â
Mechanical Diagram |
OUTPUT CABLE RECOMMEND: Â
5. Â Â STDA151B-S05~S11 output cable must with core. Â PACKING: 1. Â Net weight: 720~750g approx. 2. Â Optional output connectors available contact sales for details. |
Derating Curve |
Â
Datasheet PDF
Â
Â