Specifications
3 Year Warranty |
|
Approvals: |
Single Output |
Model Number |
Output Voltage (Factory setting, can‘t be adjusted) |
Output Current (Based on the output volt.) |
Total Regulation |
Maximum Output Power |
Typ. Efficiency |
Typ. No Load Consumption |
STDA151B-S05 |
12.0 VDC |
12.5 A |
±5% |
150W |
88% |
0.21W |
STDA151B-S06 |
15.0 VDC |
10.0 A |
±5% |
150W |
88% |
0.21W |
STDA151B-S07 |
19.0 VDC |
7.89 A |
±5% |
150W |
89% |
0.21W |
STDA151B-S08 |
24.0 VDC |
6.25 A |
±4% |
150W |
89% |
0.21W |
STDA151B-S09 |
30.0 VDC |
5.00 A |
±3% |
150W |
90% |
0.21W |
STDA151B-S10 |
36.0 VDC |
4.16 A |
±3% |
150W |
90% |
0.21W |
STDA151B-S11 |
48.0 VDC |
3.12 A |
±3% |
150W |
91% |
0.21W |
.
Electrical Characteristics |
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Operate Voltage Range |
|
90 |
|
260 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Power Factor Correction |
|
0.95 |
|
1 |
|
Output Power Range |
See Rating Chart |
|
|
150 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
|
2 |
|
A |
High Line Input Current |
Full load, Vin=240VAC |
|
0.8 |
|
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
|
|
60 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
|
|
120 |
A |
Efficiency |
Full Load, Vin=230VAC, Detail to see Rating Chart |
88 |
|
91 |
% |
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
|
|
1 |
% |
Over Voltage Protection |
Latch off, recycle input to reset |
112 |
|
132 |
% |
Over Load Protection |
Nil.But, Output protected to short circuit conditions |
|
|
|
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=110VAC |
|
|
16 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
|
|
2 |
s |
Insulation Resistance |
Primary to Secondary, 500VDC,25°XC/ 70% RH |
50 |
|
|
MΩ |
Temperature Coefficient |
All Condition |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary, limit current<10 mA |
|
|
4242 |
VDC |
EMC Emission |
Compliance to EN55032 (CISPR32), EN55024 |
B |
|
|
Class |
Environmental |
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.2 (Derate linearly from 100% load at 40°C to 50% load at 70°C) |
-20 |
|
70 |
°C |
Storage Temperature |
10~95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
4 |
kV |
Mean Time Between Failure |
Operation Temperature at 25°C, Calculated per MIL-HDBK-217F |
100k |
|
|
h |
Operating Altitude (Elevation) |
All Condition |
|
|
5000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
kV |
Mechanical Diagram |
OUTPUT CABLE RECOMMEND:
5. STDA151B-S05~S11 output cable must with core.
PACKING: 1. Net weight: 720~750g approx. 2. Optional output connectors available contact sales for details. |
Derating Curve |