Specifications
Â
1 Year Warranty |
 |
Approvals:Â |
Â
Â
Single Output |
||||
Product Number |
Range of Fixed Voltage |
Max. Output Current |
Output Regulation |
Maximum Output Power |
PTWA-012D-050200 |
5 Â VDC |
2A Max |
±7% |
10W |
PTWA-012D-090130 |
9 Â VDC |
1.3A Max |
±5% |
11.7W |
Â
Â
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
100 |
 |
240 |
VAC |
Input Frequency |
 |
50 |
 |
60 |
Hz |
Output Power Range |
 |
(See output chart) |
W |
||
Input Current (rms) |
I/P: 100-240Vac |
 |
 |
0.4 |
A |
Inrush Current |
At 100VAC, cold start, 25 °C |
 |
 |
30 |
A |
Inrush Current |
At 230VAC, cold start, 25 °C |
 |
 |
60 |
A |
Ripple & Noise |
 |
 |
 |
300 |
mVp-p |
Voltage Regulation |
Constant voltage  mode |
 |
±7 |
 |
% |
Hold-Up Time |
  Io=Full Load, Vin=115VAC |
 |
10 |
 |
mS |
Leakage Current |
 |
 |
 |
0.25 |
mA |
Efficiency |
Outpu Voltage 5VDC |
 |
79 |
 |
% |
Efficiency |
Output Voltage 9VDC |
 |
83.12 |
 |
% |
Protection |
Over voltage protection (OVP), Short circuit protection  |
||||
Automatic Recovery |
Automatic recovery when removal of protect condition.  Any protect condition shall cause no damage and no  component fail. (<0.03 ohm) |
 Â
Â
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Ambient |
0 |
 |
40 |
°C |
Storage Temperature |
Ambient |
-25 |
 |
70 |
°C |
Operating Humidity |
Non-condensing |
8 |
 |
90 |
% |
MTBF |
Full Load at 25°C Ambient Temperature |
50 |
 |
 |
K Hours |
Altitude |
 |
0 |
 |
6000 |
ft |
Â
Approvals and Compliance |
|
Parameter |
Test Conditions |
EMI |
FCC Class B, CISPR22 Class B, EN55022, EN55013 |
EMS |
IEC61000-4-2,3,4,5,6,8,11 |
Safety Description |
LVD, EN60950, EN60065, UL60950, GB8898 |
Environmental Compliance |
RoHS2, Energy Efficiency DoE Level VI |
Â
Â
Mechanical Diagram |
 |
 Note: 1.     Dimensions are shown in mm. 2.     Weight: 89g approx. (Exclude interchangeable plugs) 3.     Optional output connector   |
Â