Specifications
3 Year Warranty |
|
Approvals: |
Single Output |
PART NO. |
Setting Voltage Range (Factory setting, can‘t be adjusted) |
Output Current (Based on the output volt.) |
Maximum Output Power |
Ripple & Noise |
Total Reg. |
Typ. Efficiency |
Typ. No Load Consumption |
Hold-Up Time |
Protection Mode |
||
min |
max |
min |
max |
||||||||
(VDC) |
(VDC) |
(A) |
(A) |
(W) |
(mVp-p) |
(%) |
(%) |
(W) |
(ms) |
||
STUA100-S01 |
3.0 |
5.0 |
10.80 |
18.00 |
54 |
50 |
±7 |
70 |
5 |
16 |
Hiccup |
STUA100-S02 |
5.0 |
6.0 |
11.66 |
14.00 |
70 |
60 |
±5 |
74 |
5 |
16 |
Hiccup |
STUA100-S03 |
6.0 |
9.0 |
8.88 |
13.33 |
80 |
90 |
±5 |
78 |
5 |
16 |
Hiccup |
STUA100-S04 |
9.0 |
11.0 |
9.09 |
11.11 |
100 |
110 |
±5 |
78 |
5 |
16 |
Hiccup |
STUA100-S05 |
11.0 |
13.0 |
7.69 |
9.09 |
100 |
130 |
±3 |
80 |
5 |
16 |
Hiccup |
STUA100-S06 |
13.0 |
16.0 |
6.25 |
7.69 |
100 |
160 |
±3 |
80 |
5 |
16 |
Hiccup |
STUA100-S07 |
16.0 |
21.0 |
4.76 |
6.25 |
100 |
240 |
±3 |
80 |
5 |
16 |
Hiccup |
STUA100-S08 |
21.0 |
27.0 |
3.70 |
4.76 |
100 |
300 |
±2 |
80 |
5 |
16 |
Hiccup |
STUA100-S09 |
27.0 |
33.0 |
3.03 |
3.70 |
100 |
300 |
±2 |
80 |
5 |
16 |
Hiccup |
STUA100-S10 |
33.0 |
40.0 |
2.50 |
3.03 |
100 |
300 |
±2 |
80 |
5 |
16 |
Hiccup |
STUA100-S11 |
40.0 |
50.0 |
2.00 |
2.50 |
100 |
300 |
±2 |
82 |
5 |
16 |
Hiccup |
Electrical Characteristics |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Input Operate Voltage Range |
Detail to see Fig.1 |
90 |
|
260 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Power Factor Correction |
Io=Full load, Vin=240VAC |
0.95 |
|
1 |
|
Output Power Range |
See Rating Chart |
|
|
100 |
W |
Low Line Input Current |
Full Load, Vin=100VAC |
|
2.0 |
|
A |
High Line Input Current |
Full Load, Vin=240VAC |
|
0.83 |
|
A |
Low Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=100VAC |
|
|
50 |
A |
High Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=240VAC |
|
|
120 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
|
|
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC, Detail to see Rating Chart |
See Rating Chart |
|||
Line Regulation |
Full Load, Vin=100~120VAC |
0.5 |
|
1 |
% |
Load Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
2 |
|
5 |
% |
Over Voltage Protection |
Over Voltage Protection |
112 |
|
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
|
150 |
% |
Time of Transient Response |
Full Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
See Rating Chart |
|||
Start-up time |
Full Load, Vin=100~240VAC |
|
|
3 |
s |
Temperature Coefficient |
Full load, Vin=100~240VAC |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage (P-S) |
Primary to Secondary |
|
|
4242 |
VDC |
Dielectric Withstanding Voltage (P-G) |
Primary to PE |
|
|
2121 |
VDC |
EMC Emission |
Compliance to EN55022 (CISPR22) |
|
|
B |
Class |
Environmental |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.2 (Derate linearly from 100% load at 50°C to 50% load at 70°C) |
0 |
|
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
4 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
100k |
|
|
h |
Operating Altitude (Elevation) |
All condition |
|
|
2000 |
m |
Vibration |
10 ~ 500Hz, 10min./1cycle, 60min. each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
kV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
kV |
Mechanical Diagram & Technical Chart |
PIN Chart:
|
Note:
Derating Chart
|