Specifications
1 Year Warranty |
|
Approvals: |
Single Output |
||||
Product Number |
Output Voltage |
Max. Output Current |
Output Regulation |
Maximum Output Power |
PTWA-012A-XXXYYY |
5VDC |
2.4A Max |
±5% |
12W |
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Rated Input Voltage |
Operating Voltage |
100 |
|
240 |
VAC |
Input Frequency |
|
50 |
|
60 |
Hz |
Output Power Range |
|
0 |
|
12 |
W |
Input Current (rms) |
I/P: 100-240Vac |
|
|
0.3 |
A |
Inrush Current |
At 100VAC, cold start, 25 °C |
|
|
60 |
A |
Inrush Current |
At 230VAC, cold start, 25 °C |
|
|
90 |
A |
Ripple & Noise |
|
|
|
250 |
mVp-p |
Voltage Regulation |
Constant voltage mode |
|
±5 |
|
% |
Hold-Up Time |
Io=Full Load, Vin=115VAC |
|
10 |
|
mS |
Leakage Current |
|
|
|
0.25 |
mA |
Efficiency |
|
80 |
|
|
|
Protection |
Over voltage protection (OVP), Over Load Protection (OLP), Short circuit protection |
||||
Automatic Recovery |
Automatic recovery when removal of protect condition. Any protect condition shall cause no damage and no component fail. (<0.03 ohm) |
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Ambient |
0 |
|
40 |
°C |
Storage Temperature |
Ambient |
-10 |
|
70 |
°C |
Operating Humidity |
Non-condensing |
8 |
|
90 |
% |
MTBF |
Full Load at 25°C Ambient Temperature |
80 |
|
|
K Hours |
Approvals and Compliance |
|
Parameter |
Test Conditions |
Safety Description |
CE, IEC60950-1, UL60950-1 |
Environmental Compliance |
RoHS2, Energy Efficiency DoE Level VI |
Mechanical Diagram |
Size: 58x38x31 mm
Note: 1. Dimensions are shown in mm. 2. Weight: 57g approx. (Exclude interchangeable plugs) 3. Optional output connector
|