Print this page

PTDA-060D-B SERIES


60W Desktop Power Supply for I.T. Equipment


  • Wide Input Voltage 90 to 264 VAC, 47 to 63Hz
  • IEC-320-C8 Inlet
  • High Efficiency
  • Built-in Class B EMI Filter
  • (Output) Short Circuit & Over Voltage Protection
  • Light Weight & Compact Size

Specifications

 

 

1 Year Warranty

 

Approvals:

 

Single Output

Product Number

Output Voltage

Max. Output Current

Output Regulation

Maximum Output Power

PTDA-060D-XXXYYY-B

5 ~ 24 VDC

5.0 A max.

5%

70W

 

 

Electrical Characteristics

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Input Voltage

Rated Input Voltage

100

 

240

VAC

Input Voltage

Operating Voltage

90

 

264

VAC

Input Frequency

 

47

 

63

Hz

AC Input Current

  Vin=100VAC

 

 

1.5

A

AC Input Power Saving

  Vin=230 VAC at no load

 

 

0.3

W

Output Power Range

 

0

 

70

W

Efficiency

At 115/230Vac, 25%, 50%, 75% & 100% load

86

 

 

%

Output No-Load  Voltage

Io=Full Load

 

±5%

 

%

Output Regulation

 

 

±5%

 

%

Inrush Current

100VAC, cold start

 

 

60

A

Inrush Current

230VAC, cold start

 

 

90

A

Leakage current

 

 

 

0.25

mA

Ripple & Noise *

 

 

 

300

mV

Temperature Coefficient

All output

-0.05

 

0.05

%/°C

Hold-Up Time

Io=Full Load, Vin=115VAC

10

 

 

ms

Protection

Over voltage protection (OVP), AC recovery. Shall cause no damage.  
Short circuit protection; Auto recovery. Shall cause no damage.

* Note (Ripple & Noise)

Note:  
1. Output voltages shall be measured at output connector.

2. Ripple measurements shall be made with an oscilloscope of at least 20 MHz bandwidth. Output shall be bypassed at the connector with a 0.1uF ceramic disk capacitor and a 10uF electrolytic capacitor to simulate system loading at temperature 25°C.

 

 

Conditions

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Operating Temperature

 

0

 

40

°C

Storage Temperature

 

-10

 

70

°C

Operating Altitude

 

 

 

6000

ft

Operating relative humidity:

 

8

 

90

%

Storage relative humidity:

 

5

 

95

%

MTBF

At full load and 25°C ambient temperature

50

 

 

K Hours

 

Approvals and Compliance

Parameter

Test Conditions

Min.

Unit

HI-POT Test (Primary to secondary)

Test for 3sec at 5mA (Production test)

4525

VDC

Hi Pot Test (Primary to case)

Test for 3sec at 5mA (Production test) 

4525

VDC

Insulation Resistance

Input to output: .@500VDC

10M

ohm

EMI

FCC Part 15 Class B:2008, EN55013:2001+A1:2003+A2:2006

Safety Description

EMS, FCC, CE, UL60065,

Environmental Compliance

DoE Level VI, RoHS2

 

Mechanical Specifications

Note:

1. Dimensions are shown in mm.

2. Weight: 253g approx. (Exclude the input AC cord)

3. Optional output connector

 

 

 

Datasheet PDF

 