LTEF150G SERIES


150W Enclosed Power Supply for Industrial Equipment


  • Universal AC input range 
  • Built-in Active PFC function, PF>0.95 
  • Miniature size,high power density,high efficiency,long life and high reliability
  • Withstand 300VA surge input for 5 secs. 
  • Output protections: OLP/SCP/OPP/OVP/OTP
  • Wide operating ambient temp (-20°C~70°C) 
  • All using 105°C long life electrolytic capacitors. 
  • 100% full load burn-in test 
  • Easy assembling from top side 
  • PCB soldering side with conformal coating 
  • Suitable for critical applications

Specifications

 

 

3 Year Warranty

 

Approvals: 

 

Specification

PRODUCT NUMBER

LTEF150G-S120125 

LTEF150G -S150100 

LTEF150G -S240063 

LTEF150G-S480032 

OUTPUT 

DC Output 

12V 

15V 

24V 

48V 

Rated Current 

12.5A 

10A 

6.3A 

3.2A 

Current Range     Note 1 

0~12.5A 

0~10A 

0~6.3A 

0~3.2A 

  Ripple and Noise 

Note 2 

 0~70°C 

≤100mV 

≤100mV 

≤100mV 

≤100mV 

-20~0°C 

≤200mV 

≤200mV 

≤200mV 

≤200mV 

Voltage ADJ.  Range 

10.8~13.2V 

13.5~16.5V 

21.6~26.4V 

43.2~52.8V 

Voltage Accuracy  

±2.0% 

±2.0% 

±2.0% 

±2.0% 

Line Regulation 

±0.5% 

±0.5% 

±0.5% 

±0.5% 

Load Regulation 

±2.0% 

±2.0% 

±1.0% 

±1.0% 

Set-up Time 

≤3S /115Vac,≤2S /230Vac 

Hold up Time  

≥10mS  (220Vac input, Full load) 

Temperature Coefficient 

±0.03%/°C 

Overshoot and Undershoot 

<5.0% 

INPUT 

Voltage Range    

90Vac~264Vac 

Frequency Range 

47Hz~63Hz 

Power factor (typical) 

PF>0.98@115Vac, PF>0.95@230Vac 

Efficiency (Typical) 230Vac input 

≥86% 

≥87% 

≥87% 

≥88% 

AC Current (max.) 

<2 A 

Inrush Current (Typical) 

<30A/115Vac,<45A/230Vac      Cold start 

Leakage Current 

Input—output: ≤0.25mA    Input—PG: ≤3.5mA 

PROTECTION 

Over Load 

105%~150% of rated output current, hiccup mode, auto recovery 

Over power 

105%~150% of rated output current, hiccup mode, auto recovery 

Over Voltage 

115%~150% of rated output voltage, hiccup mode, auto recovery 

Over Temperature 

105°C+5°C(detect on Mosfet temperature);shut down,auto recovery after the temperature goes down to 60°C 

Short Circuit 

Long-term mode, auto recovery  

 

 

ENVIRONMENT 

Operating amb. Temp. & Hum. 

-20°C~70°C;  20%~90%RH  No condensing (refer to the derating curve) 

Storage Temp. & Hum. 

-30°C~85°C;  10%~95%RH  No condensing 

SAFETY &EMC  

Note 3 

Safety Standards 

UL60950-1 2nd Ed; IEC 60950-1:2005(2nd Ed) ;EN60950-1:2006 

Withstand Voltage 

Primary-Secondary:3.0KVac; ≤Ü10mA .Primary-PG:1.5KVac; ≤Ü10mA. Secondary-PG:0.5KVDC;≤Ü10mA. 

Isolation Resistance 

100M ohms  

EMS Emission 

Compliance to EN55022 Class B 

Harmonic Current 

Compliance to EN61000-3-2, Class A 

EMC Immunity 

Compliance to EN61000-4-2,3,4,5,6,8,11; heavy industry level 

OTHERS 

MTBF (MIL-HDBK-217F) 

More than 200,000Hrs (25°C, Full load) 

Dimension  (L*W*H) 

160×98.3×38mm 

Packing 

20PCS/CTN, 14KGS, 0.04CBM 

Cooling method 

Cooling by free air convection 

NOTE 

  1. All parameters NOT specially mentioned are measured at rated input, rated load and 25°C of ambient temperature. 
  2. Measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1 uF & 10uF parallel capacitor. 