Specifications
Â
1 Year Warranty |
 |
Approvals:Â |
Â
Â
Single Output |
|||||
Product Number |
AC Plug |
Range of Fixed Voltage |
Max. Output Current |
Output Regulation |
Maximum Output Power |
PTWA-018A-XXXYYY-1 |
Fixed US |
5 ~ 24 VDC |
2.5A Max |
±5% |
18W |
PTWA-018A-XXXYYY-2 |
Fixed EU |
||||
PTWA-018A-XXXYYY-3 |
Fixed UK |
||||
PTWA-018A-XXXYYY-4 |
Fixed SAA |
||||
PTWA-018A-XXXYYY-Z |
Interchangeable |
Â
Â
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
100 |
 |
240 |
VAC |
Input Frequency |
 |
50 |
 |
60 |
Hz |
Output Power Range |
 |
0 |
 |
18 |
W |
Input Current (rms) |
I/P: 100-240Vac |
 |
 |
0.5 |
A |
Inrush Current |
At 100VAC, cold start, 25 °C |
 |
 |
60 |
A |
Inrush Current |
At 230VAC, cold start, 25 °C |
 |
 |
90 |
A |
Ripple & Noise |
 |
 |
 |
250 |
mVp-p |
Voltage Regulation |
Constant voltage  mode |
 |
±5 |
 |
% |
Hold-Up Time |
  Io=Full Load, Vin=115VAC |
 |
10 |
 |
mS |
Leakage Current |
 |
 |
 |
0.25 |
mA |
Efficiency |
 |
85 |
 |
 |
 |
Protection |
Over voltage protection (OVP), Over Load Protection (OLP), Short circuit protection  |
||||
Automatic Recovery |
Automatic recovery when removal of protect condition.  Any protect condition shall cause no damage and no  component fail. (<0.03 ohm) |
 Â
Â
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Ambient |
0 |
 |
45 |
°C |
Storage Temperature |
Ambient |
-10 |
 |
70 |
°C |
Operating Humidity |
Non-condensing |
8 |
 |
90 |
% |
Storage Humidity |
Non-condensing |
5 |
 |
95 |
% |
MTBF |
Full Load at 25°C Ambient Temperature |
80 |
 |
 |
K Hours |
Â
Approvals and Compliance |
|
Parameter |
Test Conditions |
Hi-Pot Test |
4242VDC for 1minute (Sample testing); 4525VDC for 3sec (Production testing) |
Altitude |
Will operate properly at altitude between 0 ~ 6000 ft |
EMI |
FCC Part 15 Class B: 2008, EN55022, EN55013 |
EMS |
IEC61000-4-2,3,4,5,6,8 |
Safety Description |
UL60950-1, GB8898 |
Environmental Compliance |
RoHS2, Energy Efficiency DoE Level VI |
Â
Â
Mechanical Diagram |
Â
 Note: 1.     Dimensions are shown in mm. 2.     Size: L74 x W29 x H49.5 mm 3.     Weight: 165g approx. 4.     Optional output connector |
Â