Print this page

STDA100 SERIES


100W Desktop Power Supply for I.T. Equipment


  • Wide Operating Voltage 90 to 260 VAC, 47 to 63Hz
  • IEC-320-C14 input inlet
  • Single Output
  • Crowbar Mode Over Voltage Protection
  • Active Power Factor Correction
  • Energy Efficiency DoE VI 

Specifications

 

 

3 Year Warranty

 

Approvals:  

 

Single Output

Product Number

Output Voltage

Max. Output Current

Total Regulation

Max. Output Power

STDA100-S05

11 ~ 13 VDC

9.09 ~ 7.69 A

±5%

100W

STDA100-S06

13 ~ 16 VDC

7.69 ~ 6.25 A

±4%

100W

STDA100-S07

16 ~ 21 VDC

6.25 ~ 4.76 A

±4%

100W

STDA100-S08

21 ~ 27 VDC

4.76 ~ 3.70 A

±4%

100W

STDA100-S09

27 ~ 33 VDC

3.70 ~ 3.03 A

±3%

100W

STDA100-S10

33 ~ 40 VDC

3.03 ~ 2.50 A

±3%

100W

STDA100-S11

40 ~ 48 VDC

2.50 ~ 2.08 A

±3%

100W

This series is required to use AWG#16x5C/4FT output cable.

The regulation and efficiency will be changed by modified output cable.

 

Electrical Characteristics

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Safety Approvals Input Voltage Range

Safety Approval & Specification in Label

100

 

240

VAC

Operate Voltage Range

 

90

 

260

VAC

Input Frequency

Sine wave

47

 

63

Hz

Power Factor Correction

Lo=Full load, Vin=240VAC

0.95

 

1

 

Output Power Range

See Rating Chart

 

 

100

W

Low Line Input Current

Full load, Vin=100VAC

 

1.2

 

A

High Line Input Current

Full load, Vin=240VAC

 

0.5

 

A

Low Line Input Inrush Current

Full load, 25°C, Cool start, Vin=100VAC

 

 

50

A

High Line Input Inrush Current

Full load, 25°C, Cool start, Vin=240VAC

 

 

120

A

Safety Ground Leakage Current

Vin=240VAC, Fi=60Hz

 

 

0.75

mA

Efficiency

Full Load, Vin=230VAC

88

 

89

%

Line Regulation

Full Load, Vin=100~120VAC

 

 

1

%

Load Regulation

Vin=230VAC, 10~90% Load Change at Condition

3

 

5

%

Over Voltage Protection

Over Voltage Protection

112

 

132

%

Over Load Protection

  Recovers automatically after fault conditions is removed

110

 

150

%

Time of Transient Response

Io=Full Load to Half Load, Vin=110VAC

 

 

4

ms

Hold-Up Time

Full Load, Vin=100VAC

 

 

16

ms

Start Up Time

Full Load, Vin=100~240VAC

 

 

2

s

Ripple & Noise (Peak to Peak)

 

 

 

1

%

Temperature Coefficient

Full Load, Vin=100~240VAC

 

 

±0.04

%/°C

Dielectric Withstanding Voltage(P-S)

Primary to Secondary

 

 

4242

VDC

Dielectric Withstanding Voltage(P-G)

Primary to PE

 

 

2121

VDC

EMC Emission

Compliance to EN55022(CISPR22)

 

 

B

Class

 

 

Environmental

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Operating Temperature

Derate linearly from 100% load at 40℃ to 50% load at 70℃

0

 

70

°C

Storage Temperature

 10~95% RH

-40

 

85

°C

Operating Humidity

 non-condensing

0

 

95%

RH

Storage Humidity

 

0

 

95%

RH

Electro Static Discharge

Air Discharge, IEC61000-4-2

 

 

8

KV

Electro Static Discharge

Contact Discharge, IEC61000-4-2

 

 

4

KV

Mean Time Between Failure

Operation Temperature at 25℃, Calculated per MIL-HDBK-217F

100K

 

 

h

Operating Altitude (Elevation)

All Condition

 

 

2000

m

Vibration

10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes

 

 

5

G

Surge Voltage

  Line-Neutral

 

 

1

KV

Surge Voltage

  Line-PE & Neutral-PE

 

 

2

KV

 

 

Mechanical Diagram and Technical Chart

       

Note:

  1. Dimensions are shown in mm & inch
  2. Weight: approx. 460-670gs 
               (Exclude the input cord)
  3. Optional output connector.

 

 

Derating Chart:

 

1. Operating Temperature: 0 to 70°C

2. Derate linearly from 100% load at 40°C to 50% load at 70°C

 

 