Specifications
Â
3 Year Warranty |
 |
Approvals:Â |
Â
Single Output |
||||
Part Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Max Output Power |
STDA131-S05 |
12 ~ 13 VDC |
10.84 ~ 10.00 A |
±5% |
130W |
STDA131-S06 |
13 ~ 16 VDC |
10.00 ~ 8.12 A |
±5% |
130W |
STDA131-S07 |
16 ~ 21 VDC |
8.12 ~ 6.19 A |
±5% |
130W |
STDA131-S08 |
21 ~ 27 VDC |
6.19 ~ 4.81 A |
±3% |
130W |
STDA131-S09 |
27 ~ 33 VDC |
4.81 ~ 3.93 A |
±3% |
130W |
STDA131-S10 |
33 ~ 40 VDC |
3.93 ~ 3.25 A |
±3% |
130W |
STDA131-S11 |
40 ~ 50 VDC |
3.25 ~ 2.60 A |
±3% |
130W |
STDA131-S12 |
50 ~ 55 VDC |
2.60 ~ 2.36 A |
±3% |
130W |
STDA131-S05~S06 are required to use AWG#16X5C/4FT output cable.Â
STDA131-S07~S08 are required to use AWG#16X4C/4FT output cable.Â
STDA131-S09~S10 are required to use AWG#16X2C/4FT output cable.Â
STDA131-S11~S12 are required to use AWG#18x2C/4FT output cable.Â
The regulation and efficiency will be changed by modified output cable
.
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
 |
240 |
VAC |
Operate Voltage Range |
 |
90 |
 |
260 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Power Factor Correction |
Lo=Full load, Vin=240VAC |
0.95 |
 |
1 |
 |
Output Power Range |
See Rating Chart |
 |
 |
130 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
 |
1.58 |
 |
A |
High Line Input Current |
Full load, Vin=240VAC |
 |
0.65 |
 |
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
 |
 |
30 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
 |
 |
72 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
 |
 |
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC |
88 |
 |
89 |
% |
Line Regulation |
Full Load, Vin=100~120VAC |
 |
 |
1 |
% |
Load Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
3 |
 |
10 |
% |
Over Voltage Protection |
Over Voltage Protection |
112 |
 |
132 |
% |
Over Load Protection |
 Recovers automatically after fault conditions is removed |
110 |
 |
150 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
 |
 |
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
 |
 |
16 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
 |
 |
2 |
s |
Ripple & Noise (Peak to Peak) |
 |
 |
 |
1 |
% |
Temperature Coefficient |
Full Load, Vin=100~240VAC |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary |
 |
 |
4242 |
VDC |
Dielectric Withstanding Voltage(P-G) |
Primary to PE |
 |
 |
2121 |
VDC |
EMC Emission |
Compliance to EN55022(CISPR22) |
 |
 |
B |
Class |
Â
Â
Environmental |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 40â to 50% load at 70â |
0 |
 |
70 |
°C |
Storage Temperature |
 10~95% RH |
-40 |
 |
85 |
°C |
Operating Humidity |
 non-condensing |
0 |
 |
95% |
RH |
Storage Humidity |
 |
0 |
 |
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
 |
 |
8 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
 |
 |
4 |
KV |
Mean Time Between Failure |
Operation Temperature at 25â, Calculated per MIL-HDBK-217F |
100K |
 |
 |
h |
Operating Altitude (Elevation) |
All Condition |
 |
 |
3000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
 |
 |
5 |
G |
Surge Voltage |
 Line-Neutral |
 |
 |
1 |
KV |
Surge Voltage |
 Line-PE & Neutral-PE |
 |
 |
2 |
KV |
Â
Mechanical Diagram and Technical Chart |
   Â
Â
Â