Specifications
Â
3 Year Warranty |
 |
Approvals:Â |
Â
Â
Output Specification |
||||
Product Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Maximum Output Power |
STFA28 |
+3.3 VDC |
1 A |
5% |
15W |
+5 VDC |
0.9 A |
5% |
||
+6 VDC |
0.5 A |
5% |
||
+9 VDC |
0.4 A |
5% |
||
+33 VDC |
0.01A |
5% |
Â
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
90 |
 |
264 |
VAC |
Input Frequency |
 |
47 |
 |
63 |
Hz |
Output Power Range |
Vin= 90 to 264 VAC |
0 |
 |
15 |
W |
Input Current (Low Line) |
Io=Full load, Vin=115 VAC |
 |
 |
 |
A |
Input Current (High Line) |
Io=Full load, Vin= 230 VAC |
 |
 |
 |
A |
Low Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=115VAC |
 |
 |
 |
A |
High Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=230 VAC |
 |
 |
 |
A |
Efficiency |
Io=Full Load, Vin=230VAC |
 |
60 |
 |
% |
Line Regulation |
Io=Full Load |
 |
 |
1 |
% |
Load Regulation |
Vin=230VAC |
 |
 |
5 |
% |
Over Voltage Protection |
 |
 |
 |
 |
% |
Over Current Protection |
 |
 |
 |
 |
% |
Transient Response |
Io=Full Load to Half Load, Vin=100VAC |
 |
 |
 |
mS |
Hold-Up Time |
Io=Full Load, Vin=110VAC |
10 |
 |
 |
mS |
Start Up Time |
Io=Full Load, Â Â Â Â Vin=100VAC |
 |
 |
 |
S |
Ripple & Noise (Peak to Peak) |
Full Load, Vin=90VAC |
 |
2 |
 |
% |
Safety Ground Leakage Current |
Io= Full Load, Vin=240VAC |
 |
 |
 |
mA |
Temperature Coefficient |
All output |
 |
 |
 |
%/°C |
No-Load Power Consumption |
No Load, Vin=240VAC |
 |
 |
 |
W |
Â
Â
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
 |
0 |
 |
70 |
°C |
Storage Temperature |
 |
-40 |
 |
85 |
°C |
Relative Humidity |
 |
0 |
 |
95 |
% |
Operation temperature at 25â, calculated per MIL-HDBK-217FÂ |
 |
 |
 |
KHrs |
|
Derate linearly from 100% load at 50°C to 50% load at 70°C |
Â
Approvals and Compliance |
|||
Parameter |
Test Conditions |
Min. |
Unit |
Dielectric Withstanding Voltage for Primary to Secondary |
Primary to Secondary |
4242 |
VDC |
Dielectric Withstanding Voltage for Primary to Ground |
Primary to Ground |
2121 |
VDC |
Isoloation Resistance |
Test Voltage=500VDC |
50 |
MΩ |
EMI requirements for CISPR-11 |
Vin=220VAC |
B |
CLASS |
EMI requirements for FCC PART-18 |
Vin=110VAC |
B |
CLASS |
Safety Approvals |
 |
n/a |
n/a |
Environmental Compliance |
RoHS |
n/a |
n/a |
Â
Technical Chart |
   Â
Derating Chart:  1. Operating Temperature: 0 to 70°C 2. Derate linearly from 100% load at 40°C to 50% load at 70°C |
Â
Datasheet PDF
Â
Â