Specifications
Â
1 Year Warranty |
 |
Approvals:Â |
Â
Â
Single Output |
||||
Product Number |
Output Voltage |
Max. Output Current |
Output Regulation |
Maximum Output Power |
PTDA-048A-050yyy ~ 110yyy-B |
5 ~ 11 VDC |
 |
±5% |
37W |
PTDA-048A-120yyy ~ 240yyy-B |
12 ~ 24 VDC |
 |
±5% |
48W |
Â
Â
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
100 |
 |
240 |
VAC |
Input Frequency |
 |
50 |
 |
60 |
Hz |
Output Power Range |
 |
0 |
 |
37/48 |
W |
Input Current (rms) |
I/P: 100 VAC |
 |
1.0 |
 |
A |
Inrush Current |
Full load at 100 VAC |
 |
 |
60 |
A |
Inrush Current |
Full load at 230VAC |
 |
 |
90 |
A |
Voltage Regulation |
Constant voltage  mode |
 |
±5 |
 |
% |
Ripple & Noise |
 |
 |
 |
250 |
mV |
Leakage Current |
 |
 |
 |
0.25 |
mA |
Protection |
Over voltage protection (OVP), AC recycle;Â |
||||
Automatic Recovery |
Automatic recovery when removal of protect condition. Â Any protect condition shall cause no damage and no component fail. (<0.03 ohm) |
 Â
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Ambient |
0 |
 |
40 |
°C |
Storage Temperature |
Ambient |
-10 |
 |
70 |
°C |
Operating Humidity |
Non-condensed |
8 |
 |
90 |
% |
Mean Time Between Failure |
 |
80 |
 |
 |
K-Hours |
Â
Approvals and Compliance |
|
Parameter |
Test Conditions |
Safety Description |
EMI, FCC Class B, CISPR22 Class B, CE, UL60950-1 |
Â
Â
Â
Mechanical Diagram |
Â
 |
 Size (LxWxH) : 107x48x31.8mm  Note:
|
Â