Specifications
Â
1 Year Warranty |
 |
Approvals: |
Â
Single Output |
||||||
Product Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Maximum Output |
Ripple & Noise |
Typ. Efficiency |
MTWA10-S02 |
5 ~ 5.99 VDC |
1.60 ~ 1.33 A |
±5% |
 8W |
100mVp-p |
77.20% |
MTWA10-S03 |
6.5 ~ 8 VDC |
1.23 ~ 1.00 A |
±5% |
 8W |
100mVp |
80.64% |
MTWA10-S04 |
8 ~ 11 VDC |
1.25 ~ 0.91 A |
±5% |
10W |
100mVp |
81.95% |
MTWA10-S05 |
11 ~ 13 VDC |
0.91 ~ 0.77 A |
±5% |
10W |
100mVp |
81.95% |
MTWA10-S06 |
13 ~ 16 VDC |
0.77 ~ 0.63 A |
±5% |
10W |
100mVp |
81.95% |
MTWA10-S07 |
16 ~ 21 VDC |
0.63 ~ 0.48 A |
±5% |
10W |
100mVp |
81.95% |
MTWA10-S08 |
21 ~ 27 VDC |
0.48 ~ 0.37 A |
±4% |
10W |
100mVp |
81.95% |
MTWA10-S09 |
27 ~ 33 VDC |
0.37 ~ 0.30 A |
±4% |
10W |
100mVp |
83% |
MTWA10-S10 |
33 ~ 40 VDC |
0.30 ~ 0.25 A |
±4% |
10W |
100mVp |
84% |
MTWA10-S11 |
40 ~ 48VDC |
0.25 ~ 0.20 A |
±4% |
10W |
100mVp |
85% |
1. MTWA10-S02~S05 are required to use AWG#20 / 4FT output cable. 2. MTWA10-S06~S08 are required to use AWG#22 / 4FT output cable. . 3. MTWA10-S09~S11 are required to use AWG#24 / 4FT output cable. . 4. The regulation and efficiency will be changed by modified output cable.. |
||||||
 |
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
 |
240 |
VAC |
Operate Voltage Range |
 |
90 |
 |
264 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Output Power Range |
See Rating Chart |
 |
 |
10 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
 |
0.3 |
 |
A |
High Line Input Current |
Full load, Vin=240VAC |
 |
0.12 |
 |
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
25 |
 |
35 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
50 |
 |
84 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
 |
 |
0.25 |
mA |
Efficiency |
Full Load, Vin=230VAC |
77.2 |
 |
85 |
% |
Line Regulation |
Full Load, Vin=100~120VAC |
0.5 |
 |
1 |
% |
Load Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
4 |
 |
5 |
% |
Over Load Protection |
Nil. But, Output protected to short circuit conditions |
||||
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
 |
 |
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
 |
8 |
 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
 |
 |
3 |
s |
Ripple & Noise (Peak to Peak) |
 |
 |
 |
2 |
% |
Temperature Coefficient |
Full Load, Vin=100~240VAC |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary |
 |
 |
4242 |
VDC |
EMC Emission |
Compliance to EN55022(CISPR22) |
 |
 |
B |
Class |
Â
Â
Environmental |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 40â to 50% load at 70â |
0 |
 |
70 |
°C |
Storage Temperature |
 10~95% RH |
-40 |
 |
85 |
°C |
Operating Humidity |
 non-condensing |
0 |
 |
95% |
RH |
Storage Humidity |
 |
0 |
 |
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
 |
 |
8 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
 |
 |
4 |
KV |
Mean Time Between Failure |
Operation Temperature at 25â, Calculated per MIL-HDBK-217F |
100K |
 |
 |
h |
Operating Altitude (Elevation) |
All Condition |
 |
 |
2000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
 |
 |
5 |
G |
Surge Voltage |
 Line-Neutral |
 |
 |
1 |
KV |
Surge Voltage |
 Line-PE & Neutral-PE |
 |
 |
2 |
KV |
Â
Â
Mechanical Drawing and Technical Charts |
Â
2.  Derate linearly from 100% load at 40°C to 50% load at 70°C  |
Â
Note:
- Dimensions are shown in mm.
- Weight: 90g approx.
- Optional output connector.
Â