Specifications
3 Year Warranty |
|
Approvals: |
Single Output |
|||||
Product Number |
Output Voltage |
Max. Output Current |
Regulation |
Max. Output |
Approvals & Compliance |
STDA150-S08 |
24 VDC |
6.25 A |
±3% |
150W |
UL, PSE, CCC, CE, FCC, CB, DoE VI, RoHS2 |
The total regulation on STDA150-S08 is required use AWG#16 X2C/4FT output cable. The regulation and efficiency will be changed by modified output cable. |
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Operate Voltage Range |
|
90 |
|
260 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Power Factor Correction |
Lo=Full load, Vin=240VAC |
0.95 |
|
1 |
|
Output Power Range |
See Rating Chart |
|
|
150 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
|
1.89 |
|
A |
High Line Input Current |
Full load, Vin=240VAC |
|
0.78 |
|
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
|
|
30 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
|
|
75 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
|
|
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC |
|
|
89 |
% |
Line Regulation |
Full Load, Vin=100~120VAC |
|
|
1 |
% |
Load Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
|
5 |
|
% |
Over Voltage Protection |
Over Voltage Protection |
112 |
|
132 |
% |
Over Load Protection |
Recovers automatically after fault conditions is removed |
110 |
|
150 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
|
|
20 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
|
|
2 |
s |
Ripple & Noise (Peak to Peak) |
|
|
|
1 |
% |
Temperature Coefficient |
Full Load, Vin=100~240VAC |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary |
|
|
4242 |
VDC |
Dielectric Withstanding Voltage(P-G) |
Primary to PE |
|
|
2121 |
VDC |
EMC Emission |
Compliance to EN55022(CISPR22) |
|
|
B |
Class |
Environmental |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 40℃ to 50% load at 70℃ |
0 |
|
70 |
°C |
Storage Temperature |
10~95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
4 |
KV |
Mean Time Between Failure |
Operation Temperature at 25℃, Calculated per MIL-HDBK-217F |
100K |
|
|
h |
Operating Altitude (Elevation) |
All Condition |
|
|
2000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
KV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
KV |
Mechanical Diagram and Technical Chart |