Print this page

STDA16A SERIES


15W Desktop Power Supply for IT Equipment


  • Wide Operating Voltage 90 to 264 VAC, 47 to 63Hz 
  • IEC-320-C14 input inlet 
  • Optional Output Connector (See appendix)
  • Single Output
  • Class I system 
  • DoE VI, CoC v5 (tier 2) (except STDA16A-S01)

Specifications

 

 

3 Year Warranty

 

Approvals:  

 

Single Output

Part Number

Range of Fixed Voltage

Max. Output Current

Total Regulation

Max Output

* STDA16A-S01

3 ~ 5 VDC

2.50 A max

±5%

12W

   STDA16A-S02

5 ~ 5.99 VDC

2.50 ~ 2.00 A

±5%

12W

   STDA16A-S03

6 ~ 8 VDC

2.00 ~ 1.50 A

±5%

12W

   STDA16A-S04

8 ~ 11 VDC

1.87 ~ 1.36 A

±5%

15W

   STDA16A-S05

11 ~ 13 VDC

1.36 ~ 1.15 A

±5%

15W

   STDA16A-S06

13 ~ 16 VDC

1.15 ~ 0.94 A

±5%

15W

   STDA16A-S07

16 ~ 21 VDC

0.94 ~ 0.72 A

±5%

15W

   STDA16A-S08

21 ~ 27 VDC

0.72 ~ 0.55 A

±5%

15W

   STDA16A-S09

27 ~ 33 VDC

0.55 ~ 0.45 A

±5%

15W

   STDA16A-S10

33 ~ 40 VDC

0.45 ~ 0.37 A

±3%

15W

   STDA16A-S11

40 ~ 48 VDC

0.37 ~ 0.31 A

±3%

15W

STDA16A-S01 is required to use AWG#16/4FT output cable.

STDA16A-S02~S07 are required to use AWG#18/4FT output cable.

STDA16A-S08~S11 are required to use AWG#20/4FT output cable.

The regulation and efficiency will be changed by modified output cable.

 

Electrical Characteristics

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Safety Approvals Input Voltage Range

Safety Approval & Specification in Label

100

 

240

VAC

Operate Voltage Range

 

90

 

264

VAC

Input Frequency

Sine wave

47

 

63

Hz

Output Power Range

See Rating Chart

 

 

15

W

Low Line Input Current

Full load, Vin=100VAC

 

0.4

 

A

High Line Input Current

Full load, Vin=240VAC

 

0.16

 

A

Low Line Input Inrush Current

Full load, 25°C, Cool start, Vin=100VAC

35

 

45

A

High Line Input Inrush Current

Full load, 25°C, Cool start, Vin=240VAC

70

 

90

A

Safety Ground Leakage Current

Vin=240VAC, Fi=60Hz

 

 

0.75

mA

Efficiency

Full Load, Vin=230VAC

69

 

86

%

Line Regulation

Full Load, Vin=100~120VAC

0.5

 

1

%

Load Regulation

Vin=230VAC, 10~90% Load Change at Condition

3

 

7

%

Over Load Protection

Nil. But, Output protected to short circuit conditions

Time of Transient Response

Io=Full Load to Half Load, Vin=110VAC

 

 

4

ms

Hold-Up Time

Full Load, Vin=100VAC

 

 

8

ms

Start Up Time

Full Load, Vin=100~240VAC

 

 

2

s

Ripple & Noise (Peak to Peak)

 

 

 

1

%

Temperature Coefficient

Full Load, Vin=100~240VAC

 

 

±0.04

%/°C

Dielectric Withstanding Voltage(P-S)

Primary to Secondary

 

 

4242

VDC

Dielectric Withstanding Voltage (P-G)

Primary to PE

 

 

2121

VDC

EMC Emission

Compliance to EN55022(CISPR22)

 

 

B

Class

 

 

Environmental

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Operating Temperature

Derate linearly from 100% load at 40℃ to 50% load at 70℃

0

 

70

°C

Storage Temperature

 10~95% RH

-40

 

85

°C

Operating Humidity

 non-condensing

0

 

95%

RH

Storage Humidity

 

0

 

95%

RH

Electro Static Discharge

Air Discharge, IEC61000-4-2

 

 

8

KV

Electro Static Discharge

Contact Discharge, IEC61000-4-2

 

 

4

KV

Mean Time Between Failure

Operation Temperature at 25℃, Calculated per MIL-HDBK-217F

100K

 

 

h

Operating Altitude (Elevation)

All Condition

 

 

2000

m

Vibration

10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes

 

 

5

G

Surge Voltage

  Line-Neutral

 

 

1

KV

Surge Voltage

  Line-PE & Neutral-PE

 

 

2

KV

 

Mechanical Diagram and Derating Chart

       

Note:

  1. Dimensions are shown in mm & inch
  2. Weight: 165gs approx. 
               (Exclude the input cord)
  3. Optional output connector.

 

 

Derating Chart:

 

 

Datasheet PDF

 