Specifications
5 Year Warranty |
|
Approvals: |
Single Output |
|||||
Product Number |
Output Voltage |
Max. Output Current |
Regulation |
Max. Output |
Approvals & Compliance |
SIDA130-S05 |
11 ~ 13 VDC |
11.80 ~ 10.00 A |
±5% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, FCC, PSE, RoHS2 |
SIDA130-S06 |
13 ~ 16 VDC |
10.00 ~ 8.12 A |
±5% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, PSE, RoHS2 |
SIDA130-S07 |
16 ~ 21 VDC |
8.12 ~ 6.19 A |
±5% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, PSE, RoHS2 |
SIDA130-S08 |
21 ~ 27 VDC |
6.19 ~ 4.81 A |
±5% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, PSE, RoHS2 |
SIDA130-S09 |
27 ~ 33 VDC |
4.81 ~ 3.93 A |
±5% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, PSE, RoHS2 |
SIDA130-S10 |
33 ~ 40 VDC |
3.93 ~ 3.25 A |
±3% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, PSE, RoHS2 |
SIDA130-S11 |
40 ~ 50 VDC |
3.25 ~ 2.60 A |
±3% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, FCC, PSE, RoHS2 |
SIDA130-S12 |
50 ~ 55 VDC |
2.60 ~ 2.36 A |
±3% |
130W |
UL/CUL, ITS-GS, CE, CB, CCC, PSE, RoHS2 |
Dual Output |
||||||
Product Number |
Output Voltage |
Max. Output Current (Io1, Io2) |
Minimum Output |
Regulation |
Max. Output |
Approvals & Compliance |
SIDA130-D00 |
+3.3VDC, +12VDC |
20A, 2A |
4A, 0A |
±7%, ±5% |
90W |
UL/cUL,TUV-GS, CE, CB, IRAM, PSE, RoHS2 |
SIDA130-D01 |
+5VDC, +12 VDC |
20A, 2A |
4A, 0A |
±7%, ±5% |
120W |
UL/cUL,TUV-GS, CE, CB, IRAM, PSE, RoHS2 |
SIDA130-D01-1 |
+5VDC, +12 VDC |
10A, 5A |
2A, 1A |
±5%, ±10% |
110W |
UL/cUL, TUV-GS, CE, CB, IRAM, PSE, RoHS2 |
SIDA130-D02 |
+5VDC, +15 VDC |
20A, 2A |
4A, 0A |
±7%, ±5% |
120W |
UL/cUL, TUV-GS, CE, CB, IRAM, PSE, RoHS2 |
SIDA130-D03 |
+5VDC, +24 VDC |
20A, 2A |
4A, 0.2A |
±7%, ±5% |
120W |
UL/cUL, TUV-GS, CE, CB, PSE, RoHS2 |
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
90 |
|
260 |
VAC |
Input Frequency |
|
47 |
|
63 |
Hz |
Power Factor Correction |
Io=Full load, Vin=230 VAC |
0.95 |
|
1 |
|
Output Power Range |
Vin= 90 to 264 VA C |
(See output specifications) |
W |
||
Input Current (Low Line) |
Io=Full load, Vin=115 VAC |
|
|
3.2 |
A |
Input Current (High Line) |
Io=Full load, Vin= 230 VAC |
|
|
1.3 |
A |
Low Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=115VAC |
|
|
30 |
A |
High Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=230VAC |
|
|
72 |
A |
Efficiency |
Io=Full Load, Vin=230VAC |
60 |
|
80 |
% |
Line Regulation |
Io=Full Load |
0.5 |
|
1 |
% |
Load Regulation |
Vin=230VAC |
3 |
|
10 |
% |
Over Voltage Protection |
|
112 |
|
132 |
% |
Over Current Protection |
|
110 |
|
150 |
% |
Transient Response |
Io=Full Load to Half Load, Vin=100VAC |
|
|
4 |
mS |
Hold-Up Time |
Io=Full Load, Vin=110VAC |
|
|
50 |
mS |
Start Up Time |
Io=Full Load, Vin=100VAC |
|
|
3 |
S |
* Ripple & Noise (Peak to Peak) |
Full Load, Vin=90VAC |
|
1 |
2 |
% |
Safety Ground Leakage Current |
Io= Full Load, Vin=240VAC/60Hz |
|
|
0.75 |
mA |
Temperature Coefficient |
All output |
-0.04 |
|
0.04 |
%/°C |
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature (Please see the derating cruve) |
(See derating chart) |
-20 |
|
70 |
°C |
Storage Temperature |
|
-40 |
|
85 |
°C |
Operating / Storage Humidity |
No-condensing |
0 |
|
95 |
% |
MTBF Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
100 |
|
|
K Hrs |
Approvals and Compliance |
|||
Parameter |
Test Conditions |
Max |
Unit |
Dielectric Withstanding Voltage |
Primary to secondary |
4242 |
VDC |
Dielectric Withstanding Voltage |
Primary to PE |
2121 |
VDC |
Safety |
UL/c-UL0950-1:2nd Edition), TUV/GS(EN60950-1:2nd Edition) |
||
Environmental Compliance |
RoHS2 |
Mechanical Diagram and Technical Chart |
Note: 1. Dimensions are shown in mm. 2. Weight: 490-670g approx. 3. Optional output connector.
Derating Curve: |