Specifications
5 Year Warranty |
|
Approvals: |
Single Output |
||||
Model Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Max. Output Power |
SIDA41A-S02 |
5 ~ 5.99 VDC |
5A |
±5% |
30W |
SIDA41A-S03 |
6 ~ 8 VDC |
4.61 ~ 3.75 A |
±5% |
30W |
SIDA41A-S04 |
8 ~ 11 VDC |
4.38 ~ 3.18 A |
±5% |
35W |
SIDA41A-S05 |
11 ~ 13 VDC |
3.64 ~ 3.07 A |
±5% |
40W |
SIDA41A-S06 |
13 ~ 16 VDC |
3.07 ~ 2.50 A |
±5% |
40W |
SIDA41A-S07 |
16 ~ 21 VDC |
2.81 ~ 2.14 A |
±5% |
45W |
SIDA41A-S08 |
21 ~ 27 VDC |
2.38 ~ 1.85 A |
±3% |
50W |
SIDA41A-S09 |
27 ~ 33 VDC |
1.85 ~ 1.51 A |
±3% |
50W |
SIDA41A-S10 |
33 ~ 40 VDC |
1.51 ~ 1.25 A |
±2% |
50W |
SIDA41A-S11 |
40 ~ 50 VDC |
1.25 ~ 1.04 A |
±2% |
50W |
SIDA41A-S02~S04 are required to use AWG#14 / 4FT or AWG#16 / 2FT output cable.
SIDA41A-S05~S06 are required to use AWG#16 / 4FT output cable.
SIDA41A-S07~S11 are required to use AWG#18 / 6FT output cable.
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Safety Approvals Input Voltage Range |
Safety Approval & Specification in Label |
100 |
|
240 |
VAC |
Operate Voltage Range |
Derate linearly from 100% load at 90VAC to 80% load at 80VAC |
90 |
|
264 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Output Power Range |
See Rating Chart |
|
|
50 |
W |
Low Line Input Current |
Full load, Vin=100VAC |
|
1.2 |
|
A |
High Line Input Current |
Full load, Vin=240VAC |
|
0.8 |
|
A |
Low Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=100VAC |
|
|
54 |
A |
High Line Input Inrush Current |
Full load, 25°C, Cool start, Vin=240VAC |
|
|
108 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
|
|
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC |
85 |
|
88.03 |
% |
Line Regulation |
Full Load, Vin=100~120VAC |
|
|
1 |
% |
Load Regulation |
Vin=230VAC, 10~90% Load Change at Condition |
|
|
5 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
|
150 |
% |
Time of Transient Response |
Io=Full Load to Half Load, Vin=110VAC |
|
|
4 |
ms |
Hold-Up Time |
Full Load, Vin=100VAC |
10 |
|
12 |
ms |
Start Up Time |
Full Load, Vin=100~240VAC |
|
|
2 |
s |
Ripple & Noise (Peak to Peak) |
|
|
|
1 |
% |
Temperature Coefficient |
Full Load, Vin=100~240VAC |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage(P-S) |
Primary to Secondary |
|
|
4242 |
VDC |
Dielectric Withstanding Voltage(P-G) |
Primary to PE |
|
|
2550 |
VDC |
EMC Emission |
Compliance to EN55022(CISPR22) |
|
|
B |
Class |
Environmental |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Derate linearly from 100% load at 40℃ to 50% load at 70℃ |
-20 |
|
70 |
°C |
Storage Temperature |
10~95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
KV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
6 |
KV |
Mean Time Between Failure |
Operation Temperature at 25℃, Calculated per MIL-HDBK-217F |
100K |
|
|
h |
Operating Altitude (Elevation) |
All Condition |
|
|
5000 |
m |
Vibration |
10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes |
|
|
5 |
G |
Surge Voltage |
Line-Neutral |
|
|
1 |
KV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
KV |
Mechanical Diagram and Technical Chart |
Note:
Derating Chart: 1. Operating Temperature: -20 to 70°C 2. Derate linearly from 100% load at 40°C to 50% load at 70°C |
Datasheet PDF