Specifications
Â
5 Year Limited Warranty |
 |
(Compliant with UL60950-1, EN60950-1, CSA, CE, RoHS) |
Â
Single Output |
 | ||||
Part Number |
Output Voltage |
Max. Output Current |
Load Regulation |
Maximum Output Power |
|
SINA150-S05 |
12 VDC |
12.5 A |
±5% |
150W |
|
SINA150-S08 |
24 VDC |
6.25 A |
±3% |
150W |
|
SINA150-S09 |
30 VDC |
5.00 A |
±2% |
150W |
 |
SINA150-S10 |
36 VDC |
4.17 A |
±2% |
150W |
 |
SINA150-S11 |
48 VDC |
3.13 A |
±2% |
150W |
 |
Â
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
90 |
 |
260 |
VAC |
Input Frequency |
 |
47 |
 |
63 |
Hz |
Power Factor Correction |
Io=Full load, Vin=90~260VAC |
0.95 |
0.97 |
1.00 |
 |
Output Power Range |
Vin= 90 to 264 VA C |
0 |
 |
150 |
W |
Input Current (Low Line) |
Io=Full load, Vin=115 VAC |
 |
 |
2.0 |
A |
Input Current (High Line) |
Io=Full load, Vin= 230 VAC |
 |
 |
0.8 |
A |
Low Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=115VAC |
 |
48 |
54 |
A |
High Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=230VAC |
 |
58 |
60 |
A |
Efficiency |
Io=Full Load, Vin=230VAC |
82 |
88 |
90 |
% |
Line Regulation |
Io=Full Load |
 |
0.5 |
1 |
% |
Load Regulation |
Vin=230VAC |
2 |
 |
5 |
% |
Over Voltage Protection |
 |
112 |
 |
132 |
% |
Over Current Protection |
 |
110 |
 |
150 |
% |
Transient Response |
Io=Full Load to Half Load, Vin=100VAC |
 |
 |
4 |
mS |
Hold-Up Time |
Io=Full Load, Vin=110VAC |
 |
100 |
 |
mS |
Start Up Time |
Io=Full Load, Vin=100VAC |
0.3 |
1 |
2 |
S |
Ripple & Noise (Peak to Peak) |
Full Load, Vin=90VAC / 47uF capacitor / 20MHz |
 |
 |
1 |
% |
Safety Ground Leakage Current |
Io= Full Load, Vin=240VAC/60Hz |
 |
 |
0.5 |
mA |
Temperature Coefficient |
All output |
-0.04 |
 |
0.04 |
%/°C |
Â
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Relative Humidity: 10 ~ 95% |
-10 |
 |
70 |
°C |
Storage Temperature |
Relative Humidity: 5 ~ 95% |
-40 |
 |
85 |
°C |
MTBF :  Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
0.1 |
 |
 |
M Hrs |
|
De-rate linearly from 100% load at 50°C to 50% load at 70°C |
Â
Approvals and Compliance |
|||
Parameter |
Test Conditions |
Min. |
Unit |
Dielectric Withstanding Voltage for Primary to secondary |
Primary to secondary |
4242 |
VDC |
Dielectric Withstanding Voltage for Primary to Ground |
Primary to ground |
2121 |
VDC |
Isolation Resistance |
Test Voltage = 2100VDC |
50 |
MΩ |
EMI requirements for CISPR-11 |
Vin=220VAC |
B |
CLASS |
EMI requirements for FCC PART-18 |
Vin=110VAC |
B |
CLASS |
Safety Certification |
(Certification s will be applied upon request) |
n/a |
n/a |
Environmental Compliance |
RoHS |
n/a |
n/a |
Safety, EMI, and EMC Compliance |
Safety:
 EMC/EMI:
 Electromagnetic Immunity of Power Unit:
Â
 |
Â
Â
Datasheet PDF
Â
Â