Specifications
Â
5 Year Warranty |
 |
Approvals:Â |
Â
Â
Single Output |
 | ||||
Part Number |
Output Voltage |
Max. Output Current |
Total Regulation |
Maximum Output Power |
|
SILA180-S05 |
12 VDC |
14.58 A |
5% |
175W |
|
SILA180-S08 |
24 VDC |
7.50 Â A |
3% |
180W |
|
SILA180-S11 |
48 VDC |
3.75 A |
2% |
180W |
 |
Â
Electrical Characteristics |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Input Voltage |
Operating Voltage |
100 |
 |
240 |
VAC |
Input Frequency |
 |
47 |
 |
63 |
Hz |
Power Factor Correction |
Io=Full load, Vin=90~260VAC |
0.95 |
0.97 |
1.00 |
 |
Output Power Range |
Vin= 90 to 264 VA C |
0 |
 |
180 |
W |
Input Current (Low Line) |
Io=Full load, Vin=115 VAC |
 |
 |
2.3 |
A |
Input Current (High Line) |
Io=Full load, Vin= 230 VAC |
 |
 |
0.9 |
A |
Low Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=115VAC |
 |
48 |
54 |
A |
High Line Inrush Current |
Io=Full load, 25°C, Cool start, Vin=230VAC |
 |
100 |
108 |
A |
Efficiency |
Io=Full Load, Vin=230VAC |
85 |
88 |
90 |
% |
Line Regulation |
Io=Full Load |
 |
0.5 |
1 |
% |
Load Regulation |
Vin=230VAC |
 |
3 |
5 |
% |
Over Voltage Protection |
 |
112 |
 |
132 |
% |
Over Current Protection |
 |
110 |
 |
150 |
% |
Transient Response |
Io=Full Load to Half Load, Vin=100VAC |
 |
 |
4 |
mS |
Hold-Up Time |
Io=Full Load, Vin=110VAC |
16 |
 |
 |
mS |
Start Up Time |
Io=Full Load, Vin=100VAC |
0.3 |
1 |
2 |
S |
Ripple & Noise (Peak to Peak) |
Full Load, Vin=90VAC |
 |
0.5 |
1 |
% |
Safety Ground Leakage Current |
Io= Full Load, Vin=240VAC/60Hz |
 |
0.5 |
0.75 |
mA |
Temperature Coefficient |
All output |
-0.04 |
 |
0.04 |
%/°C |
 |
Â
Â
Conditions |
|||||
Parameter |
Test Conditions |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
 |
-20 |
 |
70 |
°C |
Storage Temperature |
 |
-40 |
 |
85 |
°C |
Relative Humidity |
 |
5 |
 |
95 |
% |
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
0.1 |
 |
 |
M Hrs |
|
De-rate linearly from 100% load at 50°C to 50% load at 70°C |
Â
Approvals and Compliances |
|||
Parameter |
Test Conditions |
Min. |
Unit |
Dielectric Withstanding Voltage for Primary to secondary |
Primary to secondary |
4242 |
VDC |
Dielectric Withstanding Voltage for Primary to Ground |
Primary to ground |
2121 |
VDC |
Isolation Resistance |
Test Voltage = 2100VDC |
50 |
MΩ |
EMI requirements for CISPR-11 |
Vin=220VAC |
B |
CLASS |
EMI requirements for FCC PART-18 |
Vin=110VAC |
B |
CLASS |
Safety UL/c-UL, TUV/T-mark, CE |
UL 60950-1, EN 60950-1 |
n/a |
n/a |
RoHS compliant |
 |
n/a |
n/a |
Â
Mechanical and PIN out |
   Â
PIN CHART
|
Note:
|
||||||||||||||||||
|
Â
Datasheet PDF
Â
Â