Print this page

SIUA150 SERIES


150W U-Bracket Type for Industrial Equipment


  • Wide Operating Voltage 90 to 260 VAC, 47 to 63 Hz
  • Internal EMI Filter
  • Active Power Factor Correction
  • Crowbar Mode Over Voltage Protection
  • Synchronous Rectification
  • Single Output
  • Operating Temperature: -20°C ~ 70°C

Specifications

 

 

5 Year Warranty

 

Approvals:

 

Single Output

Model Number

Output Voltage

Output Current

Total Regulation

Maximum Output Power

SIUA150-S04

9 VDC

16.0 A

±5%

144W

SIUA150-S05

12 VDC

12.5 A

±5%

150W

SIUA150-S06

15 VDC

10.0 A

±5%

150W

SIUA150-S07

18 VDC

8.33 A

±4%

150W

SIUA150-S08

24 VDC

6.25 A

±3%

150W

SIUA150-S09

30 VDC

5.00 A

±2%

150W

SIUA150-S10

36 VDC

4.17 A

±2%

150W

SIUA150-S11

48 VDC

3.13 A

±2%

150W

 

Electrical Characteristics

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Safety Approvals Input Voltage Range

Safety Approval & Specification in Label

100

 

240

VAC

Operate Voltage Range

 

90

 

260

VAC

Input Frequency

Sine wave

47

 

63

Hz

Power Factor Correction

lo=Full load Vin=240VAC

0.95

 

1

 

Output Power Range

See Rating Chart

 

 

150

W

Low Line Input Current

Full load, Vin=100VAC

 

2.0

 

A

High Line Input Current

Full load, Vin=240VAC

 

0.8

 

A

Low Line Input Inrush Current

Full load, 25°C, Cool start, Vin=100VAC

 

 

40

A

High Line Input Inrush Current

Full load, 25°C, Cool start, Vin=240VAC

 

 

100

A

Safety Ground Leakage Current

Vin=240VAC, Fi=60Hz

 

 

0.75

mA

Efficiency

Full Load, Vin=230VAC

83

 

86

%

Line Regulation

Full Load, Vin=100~120VAC

0.5

 

1

%

Load Regulation

Vin=230VAC, 10~90% Load Change at Condition

2

 

5

%

Over Voltage Protection

Over Voltage Protection

112

 

132

%

Over Load Protection

Recovers automatically after fault condition is removed

110

 

150

%

Time of Transient Response

Io=Full Load to Half Load, Vin=110VAC

 

 

4

ms

Hold-Up Time

Full Load, Vin=100VAC

 

 

16

ms

Start Up Time

Full Load, Vin=100~240VAC

 

 

3

s

Ripple & Noise (Peak to Peak)

 

 

 

1

%

Temperature Coefficient

Full Load, Vin=100~240VAC

 

 

±0.04

%/°C

Dielectric Withstanding Voltage(P-S)

Primary to Secondary

 

 

4242

VDC

Dielectric Withstanding Voltage(P-G)

Primary to PE

 

 

2121

VDC

EMC Emission

Compliance to EN55022(CISPR22)

 

 

B

Class

 

 

Environmental

Parameter

Test Conditions

Min.

Typ.

Max.

Unit

Operating Temperature

Derate linearly from 100% load at 50℃ to 50% load at 70℃

-20

 

70

°C

Storage Temperature

 10~95% RH

-40

 

85

°C

Operating Humidity

 non-condensing

0

 

95%

RH

Storage Humidity

 

0

 

95%

RH

Electro Static Discharge

Air Discharge, IEC61000-4-2

 

 

8

KV

Electro Static Discharge

Contact Discharge, IEC61000-4-2

 

 

4

KV

Mean Time Between Failure

Operation Temperature at 25℃, Calculated per MIL-HDBK-217F

100K

 

 

h

Operating Altitude (Elevation)

All Condition

 

 

2000

m

Vibration

10~500Hz,10min./1cycle, 60min.each along X, Y, Z axes

 

 

5

G

Surge Voltage

  Line-Neutral

 

 

1

KV

Surge Voltage

  Line-PE & Neutral-PE

 

 

2

KV

 

Mechanical Diagram and Technical Chart

       

PIN CHART

PIN

MODEL

1

2

3

4

5

6

7

8

9

10

11

12

13

optional

SIUA150-SXX

OUT

OUT

OUT

OUT

OUT

OUT

RTN

RTN

RTN

RTN

RTN

RTN

PFD

 

Note:

  1. Dimensions are shown in inches or mm.
  2. Weight: 560gs approx.
  3. Input connector mates with Molex housing 09-52-4054 and Molex 2478 series crimp terminal.
  4. Output connector mates with Molex housing 09-52-4134 and Molex 2478 series crimp terminal

 

 

 

 

Derating Chart:

1. Operating Temperature: -20 to 70°C

2. Derate linearly from 100% load at 50°C to 50% load at 70°C

 

Datasheet PDF

 