Specifications
Â
2 Year Warranty |
 |
Approvals: Â (Preliminary)Â |
Â
Single Output |
MODEL NO. |
Current (max.) |
Setting Voltage Range |
Maximum Output Power |
Typ. Efficiency |
Typ. No Load Consumption |
(A) |
(VDC) |
(W) |
(%) |
(W) |
|
SEDA170-S12 |
3 |
32 ~ 57.4±0.3 |
173 |
93 |
1 |
Electrical Characteristics |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
100 |
 |
240 |
VAC |
Input Operate Voltage Range |
Detail to see Fig.1 |
90 |
 |
264 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Power Factor Correction |
 |
0.95 |
 |
1 |
 |
Output Power Range |
See Rating Chart |
 |
 |
173 |
W |
Low Line Input Current |
Full Load, Vin=100VAC |
 |
2.3 |
 |
A |
High Line Input Current |
Full Load, Vin=240VAC |
 |
1.1 |
 |
A |
Low Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=100VAC |
 |
 |
60 |
A |
High Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=240VAC |
 |
 |
120 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
 |
 |
0.25 |
mA |
Efficiency |
Full Load, Vin=230VAC, Detail  to see Rating Chart |
See Rating Chart |
|||
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
 |
 |
1 |
% |
Insulation Resistance |
 |
50 |
 |
 |
MΩ |
Temperature Coefficient |
All Condition |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage (P-S) |
Primary to Secondary, limit current <10mA |
 |
 |
4242 |
VDC |
Dielectric Withstanding Voltage (P-G) |
Primary to PE, limit current <10mA |
 |
 |
2121 |
VDC |
EMC Emission |
Meet EN55032 (CISPR32), EN55014 |
B |
 |
 |
Class |
Environmental |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Operating Temperature |
Detail to see Fig.1 (Derate linearly from 100% load at 40°C to 50% load at 70°C) |
-10 |
 |
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-20 |
 |
60 |
°C |
Operating Humidity |
non-condensing |
10 |
 |
95% |
RH |
Storage Humidity |
 |
10 |
 |
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
 |
 |
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
 |
 |
4 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C, Calculated per MIL-HDBK-217F |
50k |
 |
 |
h |
Surge Voltage |
Line-Neutral |
 |
 |
1 |
kV |
Â