Specifications
2 Year Warranty |
|
Approvals: |
Single Output |
MODEL NO. |
Current (max.) |
Setting Voltage Range |
Maximum Output Power |
Total Regulation |
Typ. Efficiency |
Typ. No Load Consumption |
(A) |
(VDC) |
(W) |
(%) |
(%) |
(W) |
|
SEEA700-S13 |
12 |
39 ~ 58.1 |
697 |
±2 |
87 |
10 |
Electrical Characteristics |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
110 |
|
240 |
VAC |
Input Operate Voltage Range |
Detail to see Fig.1 |
99 |
|
264 |
VAC |
Input Frequency |
Sine wave |
47 |
|
63 |
Hz |
Power Factor Correction |
|
0.90 |
|
1 |
|
Output Power Range |
See Rating Chart |
|
|
697 |
W |
Low Line Input Current |
Full Load, Vin=100VAC |
|
8.5 |
|
A |
High Line Input Current |
Full Load, Vin=240VAC |
|
3.5 |
|
A |
Low Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=120VAC |
|
|
50 |
A |
High Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=240VAC |
|
|
108 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
|
|
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC, Detail to see Rating Chart |
See Rating Chart |
|||
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
|
|
1 |
% |
Over Voltage Protection |
|
112 |
|
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
|
150 |
% |
Insulation Resistance |
|
50 |
|
|
MΩ |
Temperature Coefficient |
All Condition |
|
|
±0.04 |
%/°C |
Dielectric Withstanding Voltage (P-S) |
Primary to Secondary, limit current <10mA |
|
|
4242 |
VAC |
Dielectric Withstanding Voltage (P-G) |
Primary to PE, limit current <10mA |
|
|
2121 |
VAC |
EMC Emission |
Meet EN55032 (CISPR32), EN55024-1-2 |
A |
|
|
Class |
Environmental |
Condition |
Min. |
Typ. |
Max. |
Unit |
|
Operating Temperature |
Detail to see Fig.1 (Derate linearly from 100% load at 50°C to 50% load at 70°C) |
-20 |
|
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-40 |
|
85 |
°C |
Operating Humidity |
non-condensing |
0 |
|
95% |
RH |
Storage Humidity |
|
0 |
|
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
|
|
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
|
|
6 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C and nominal load, Calculated per MIL-HDBK-217F |
100k |
|
|
h |
Surge Voltage |
Line-Neutral |
|
|
1 |
kV |
Surge Voltage |
Line-PE & Neutral-PE |
|
|
2 |
kV |
General Specifications |
|
Parameter |
Standards |
Short Circuit Protection |
Auto Recovery |
Cooling |
Forced Air |
Protection Classes |
Class I |
Flammability Rating |
UL94V-1 |
Safety |
IEC 60950-1:2005/A2:2013, EN 60950-1:2006/A2:2013 |
Mechanical Drawing and Technical Charts |