Specifications
Â
2 Year Warranty |
 |
Approvals: Â |
Â
Â
Single Output |
MODEL NO. |
Current (max.) |
Setting Voltage Range |
Maximum Output Power |
Total Regulation |
Typ. Efficiency |
Typ. No Load Consumption |
(A) |
(VDC) |
(W) |
(%) |
(%) |
(W) |
|
SEEA700-S13 |
12 |
39 ~ 58.1 |
697 |
±2 |
87 |
10 |
Â
Electrical Characteristics |
Characteristic |
Condition |
Min. |
Typ. |
Max. |
Unit |
Safety Approval Input Voltage Range |
Safety Approval & Specification in Label |
110 |
 |
240 |
VAC |
Input Operate Voltage Range |
Detail to see Fig.1 |
99 |
 |
264 |
VAC |
Input Frequency |
Sine wave |
47 |
 |
63 |
Hz |
Power Factor Correction |
 |
0.90 |
 |
1 |
 |
Output Power Range |
See Rating Chart |
 |
 |
697 |
W |
Low Line Input Current |
Full Load, Vin=100VAC |
 |
8.5 |
 |
A |
High Line Input Current |
Full Load, Vin=240VAC |
 |
3.5 |
 |
A |
Low Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=120VAC |
 |
 |
50 |
A |
High Line Input Inrush Current |
Full Load, 25°C, Cool start, Vin=240VAC |
 |
 |
108 |
A |
Safety Ground Leakage Current |
Vin=240VAC, Fi=60Hz |
 |
 |
0.75 |
mA |
Efficiency |
Full Load, Vin=230VAC, Detail  to see Rating Chart |
See Rating Chart |
|||
Line Regulation |
Full Load, Vin=100~120VAC or 200~240VAC |
 |
 |
1 |
% |
Over Voltage Protection |
 |
112 |
 |
132 |
% |
Over Load Protection |
Recovers automatically after fault condition is removed |
110 |
 |
150 |
% |
Insulation Resistance |
 |
50 |
 |
 |
MΩ |
Temperature Coefficient |
All Condition |
 |
 |
±0.04 |
%/°C |
Dielectric Withstanding Voltage (P-S) |
Primary to Secondary, limit current <10mA |
 |
 |
4242 |
VAC |
Dielectric Withstanding Voltage (P-G) |
Primary to PE, limit current <10mA |
 |
 |
2121 |
VAC |
EMC Emission |
Meet EN55032 (CISPR32), EN55024-1-2 |
A |
 |
 |
Class |
Â
Environmental |
Condition |
Min. |
Typ. |
Max. |
Unit |
|
Operating Temperature |
Detail to see Fig.1 (Derate linearly from 100% load at 50°C to 50% load at 70°C) |
-20 |
 |
70 |
°C |
Storage Temperature |
10 ~ 95% RH |
-40 |
 |
85 |
°C |
Operating Humidity |
non-condensing |
0 |
 |
95% |
RH |
Storage Humidity |
 |
0 |
 |
95% |
RH |
Electro Static Discharge |
Air Discharge, IEC61000-4-2 |
 |
 |
8 |
kV |
Electro Static Discharge |
Contact Discharge, IEC61000-4-2 |
 |
 |
6 |
kV |
Mean Time Between Failure |
Operating Temperature at 25°C and nominal load, Calculated per MIL-HDBK-217F |
100k |
 |
 |
h |
Surge Voltage |
Line-Neutral |
 |
 |
1 |
kV |
Surge Voltage |
Line-PE & Neutral-PE |
 |
 |
2 |
kV |
Â
Â
General Specifications |
|
Parameter |
Standards |
Short Circuit Protection |
Auto Recovery |
Cooling |
Forced Air |
Protection Classes |
Class I |
Flammability Rating |
UL94V-1 |
Safety |
IEC 60950-1:2005/A2:2013, EN 60950-1:2006/A2:2013 |
Â
Mechanical Drawing and Technical Charts |
   Â
Â